Setting Unit Policieswww.3ware.com 123To enable or disable queuing for a unit through 3DM1 Choose Management > Controller Settings from the menu bar in 3DM.2 In the Unit Policies section of the Controller Settings page, enablequeuing by checking the box under “Queuing” for the designated unit;disable it by unchecking the box.The page refreshes, and a message at the top confirms the change that youhave made.To enable or disable queuing for a unit through 3BM1 At the main 3BM screen, select the unit by highlighting it and pressing Enter.An asterisk appears in the left-most column to indicate that it is selected.2 Tab to the Maintain Unit button and press Enter.3 On the pop-up menu, select Configure and press Enter.4 In the Configure Disk Array screen, Tab to the field Drive QueuingMode.5 Press Enter to display the choices, use the arrow keys to select the settingyou want (Enabled or Disabled), and press Enter again to choose it.6 Tab to the OK button and press Enter to select it.You return to the main 3BM screen.7 When you are finished making changes, press F8 to save them and exit3BM.Setting the StorSave Profile for a UnitYou can set the desired level of data protection versus performance for a unitby selecting the StorSave Profile. Three profiles are provided: Protection(maximum data protection), Performance (maximum performance, less dataprotection), and Balanced (a middle ground). The default is Protection.Note: Not all drives support command queuing. If a drive does not supportcommand queuing, the policy setting for the controller is ignored. Queuinginformation for SAS is not available.