Troubleshooting266 3ware SAS/SATA RAID Software User Guide, Version 9.5.1To lower the likelihood of getting this error, schedule regular verifications.See Also“Setting Overwrite ECC (Continue on Source Error When Rebuilding)” onpage 121.“Scheduling Background Tasks” on page 1730005 Rebuild completedEvent TypeInformationCauseThe 3ware RAID controller has successfully completed a rebuild. The data isnow redundant.ActionNone required.0006 Incomplete unit detectedEvent TypeWarningCauseThe 3ware RAID controller has detected an incomplete unit.An incomplete unit is a unit in which the 3ware RAID controller is unable todetect one or more drives. The drives may be missing, dead, or improperlyconnected. A unit that is incomplete is also degraded (although a degradedunit can be complete if all drives are still detected, including the failed drive).ActionCheck hardware connections and reseat the drives. Rescan the controller from3DM to see if the unit has been restored. If you are able to restore the unitbefore any data has been written to the unit, a rebuild will not be necessary. Ifthe unit remains incomplete, replace the missing or dead drives and initiate arebuild.