Error and Notification Messageswww.3ware.com 269ActionIf you see this message, the drive repairs may lie outside of the 3ware RAIDcontroller’s abilities.Try running the drive manufacturer’s diagnostic andrepair utilities on the drive.If necessary, replace the drive.See AlsoFor links to drive manufacturer diagnostic utilities and troubleshootingadvice, see http://www.3ware.com/KB/article.aspx?id=10894.000B Rebuild startedEvent TypeInformationCauseThe 3ware RAID controller started to rebuild a degraded unit. The rebuildmay have been initiated by you, may have started automatically on a hot spareor may have started after drive removal or insertion (due to the Auto Rebuildpolicy).ActionAllow the rebuild to complete. This will return the unit to its normalredundant state.See Also“Scheduling Background Tasks” on page 173“Rebuilding Units” on page 167“Background Task Prioritization” on page 173000C Initialize startedEvent TypeInformationCauseThe 3ware RAID controller started an initialization. This is always a“synching” background initialization and does not erase user data.Initialization either occurs at unit creation time for larger RAID 5, 6, or 50units or later during the initial verification of redundant units.