Error and Notification Messageswww.3ware.com 279place during off-hours. For more information, see “Scheduling BackgroundTasks” on page 166. You can also set the initialization process to go slowerand use fewer system resources. For more information, see “SettingBackground Task Rate” on page 165. (Initialization occurs at the Rebuildrate.)See Also“About Initialization” on page 158002B Verify completedEvent TypeInformationCauseVerification of the data integrity of a unit was completed successfully.See Also“About Verification” on page 162002C Source drive ECC error overwrittenEvent TypeErrorCauseA read error was encountered during a rebuild and the controller is configuredto ‘ignore ECC’ or to ‘Force continue on source errors’. The sector in errorwas reallocated.This will cause uncorrectable blocks to be rewritten, but thedata may be incorrect.ActionIt is recommended that you execute a file system check when the rebuildcompletes.Under Windows, right-click on your drive icon and choose Properties>Tools> Check Now.Under Linux or FreeBSD use fsck /dev/sda1. If you have more than oneSATA device, substitute the correct drive letter and partition number, such assdb2, for sda1.