Troubleshooting270 3ware SAS/SATA RAID Software User Guide, Version 9.5.1ActionAllow the initialization to complete. This will return the unit to its normalredundant state.See AlsoFor more information, see “About Initialization” on page 158000E Initialize failedEvent TypeErrorCauseThe 3ware RAID controller was unable to complete the initialization. Thiserror can be caused by unrecoverable drive errors.If this unit was a redundant unit, and the initialization failed because of aproblem on a particular disk drive, then the unit will be degraded.ActionIf the unit was degraded, then rebuild the unit. This may necessitate replacingthe drive.Check physical cable and power connections. You can also run the drivemanufacturer’s diagnostic and repair utilities on the drive.See AlsoFor links to drive manufacturer diagnostic utilities and troubleshootingadvice, see http://www.3ware.com/KB/article.aspx?id=10894.“Basic Troubleshooting: Check This First” on page 251000F SMART threshold exceededEvent TypeWarningCauseSMART monitoring is predicting a potential drive failure.The 3ware RAID controller supports SMART monitoring, whereby theindividual drives automatically monitor certain parametric information such