Troubleshooting280 3ware SAS/SATA RAID Software User Guide, Version 9.5.1002D Source drive error occurredEvent TypeErrorCauseAn error on the source drive was detected during a rebuild operation. Therebuild has stopped as a result.ActionThe controller will report an error, even if the area of the source drive that hadthe error did not contain data. Scheduling regular verifies will lessen thechance of getting this error.You can force the rebuild to continue by setting the Overwrite ECC Errorpolicy through 3DM, CLI, or 3BM, and then rebuilding the unit again. Thiswill cause uncorrectable blocks to be rewritten, but the data may be incorrect.It is recommended that you execute a file system check when the rebuildcompletes.Under Windows, right-click on your drive icon and choose Properties>Tools> Check Now.Under Linux or FreeBSD use fsck /dev/sda1. If you have more than oneSATA device, substitute the correct drive letter and partition number, such assdb2, for sda1.See Also“Starting a Verify Manually” on page 165“Enabling or Disabling Auto Verify for a Unit” on page 120“Setting Overwrite ECC (Continue on Source Error When Rebuilding)” onpage 121002E Replacement drive capacity too smallEvent TypeErrorCauseThe storage capacity of the drive you are using as a replacement drive is toosmall and cannot be used.