74 ParametersSummary of parameter groups01 Actual values Basic signals for monitoring of the drive. 7603 Input references Values of references received from various sources. 7704 Warnings and faults Information on warnings and faults that occurred last. 7705 Diagnostics Various run-time-type counters and measurements related to drivemaintenance.7806 Control and status words Drive control and status words. 7907 System info Drive hardware and firmware information. 8210 Standard DI, RO Configuration of digital inputs and relay outputs. 8311 Standard DIO, FI, FO Configuration of digital input/outputs and frequency inputs/outputs. 8812 Standard AI Configuration of analog inputs. 9313 Standard AO Configuration of analog outputs. 9519 Operation mode Selection of external control location sources and operatingmodes.9920 Start/stop/direction Start/stop/direction and run/start/jog enable signal sourceselection; positive/negative reference enable signal sourceselection.10021 Start/stop mode Start and stop modes; emergency stop mode and signal sourceselection; DC magnetization settings; autophasing modeselection.10822 Speed reference selection Speed reference selection. 11323 Speed reference ramp Speed reference ramp settings. 11924 Speed referenceconditioningSpeed error calculation; speed error window control configuration;speed error step.12325 Speed control Speed controller settings. 12626 Torque reference chain Settings of the torque reference chain. 13128 Frequency reference chain Settings of the frequency reference chain. 13530 Limits Drive operation limits. 14331 Fault functions Settings that define the behavior of the drive upon fault situations. 14532 Supervision Configuration of signal supervision functions 1…3. 15033 Maintenance timer &counterConfiguration of maintenance timers/counters. 15335 Motor thermal protection Motor thermal protection settings. 15936 Load analyzer Peak value and amplitude logger settings. 16640 Process PID set 1 Parameter values for process PID control. 16941 Process PID set 2 A second set of parameter values for process PID control. 18043 Brake chopper Settings of the internal brake chopper. 18144 Mechanical brake control Configuration of mechanical brake control. 18345 Energy efficiency Settings of the energy savings calculator. 18746 Monitoring/scaling settings Speed supervision settings; actual signal filtering; general scalingsettings.18947 Data storage Data storage parameters that can be written to and read fromusing other parameters’ source and target settings.19149 Panel port communication Communication settings for the control panel port on the drive. 19350 Fieldbus adapter (FBA) Fieldbus communication configuration. 193