2 Installation2.2.8. Fitting the upper arm cable package - IRBDP MH 3 UE813HAC027309-001 Revision: D© Copyright 2006-2010 ABB. All rights reserved.2.2.8. Fitting the upper arm cable package - IRBDP MH 3 UELocation of upper arm cable package - IRBDP MH 3 UEThe location of the cable package IRBDP MH 3 UE, is shown in the figure below.xx0700000580Required equipmentThe following eqiupment is required for fitting the cable package IRBDP MH 3 UE.A Metal clamp with rubber clampB Bracket for metal clampC Connection plate ax 3 (delivered with cable package IRBDP MH 3 LE)D Metal clamp with rubber clamp (right)E Bracket at wristF Metal clamp with rubber clamp (left)G Gripping clamp & clamp halfH Protection hoseEquipment Art. no NoteLocking liquid 3HAB7116-1 Loctite 243For locking screws.Standard toolkit, DressPack/SpotPack 3HAC17290-7 The contents are defined insection Toolkits, DressPack/SpotPack on page 257.Other tools and procedures may berequired. See references to theseprocedures in the step-by-step instruc-tions below.These procedures includereferences to the tools required.Continues on next page