Safewatch Pro 3000 Installation Instructions4-4FIELD TITLE and DATA ENTRIES EXPLANATION*54 Dynamic Signaling Delay0 = disabled (both signals sent)1–15 = entry times a 15-second delay.e.g., 1 = 15 seconds, 2 = 30 seconds, etc.Intended for use with Long Range Radio reporting.This field lets you select the time the panel should wait foracknowledgment from the first reporting destination (see ∗55) beforeit attempts to send a message to the second destination. Delays canbe selected from 0 to 225 seconds, in 15-second increments. Thisdelay is per message. If ”0” is entered in this field, the control panelwill send redundant reports to both Primary Dialer and LRR.UL installations must be 0 (no delay).*55 Dynamic Signaling Priority0 = Primary dialer first;1 = Long Range Radio (LRR) first.Intended for use with Long Range Radio reporting.You must enable field ∗29, OUTPUT TO LONG RANGE RADIO, ifusing this feature.You can select the initial reporting destination for messages,Primary Dialer or Long Range Radio as follows:Primary Dialer First selected (0):• If acknowledged before delay expires (see ∗54), then message willnot be sent to LRR.• If not acknowledged before delay expires, then message is sent toboth the Primary Phone No. and LRR.Long Range Radio First selected (1):• If acknowledged before delay expires, then message will not besent to the primary dialer.• If not acknowledged before delay expires, then message is sent toboth the Primary Phone No. and LRR.System Status Report Codes (∗59–∗68)Report codes can be programmed using interactive Q56 or Q58 Zone Programming modes, or codescan be entered in the following data fields.Contact ID Reporting: Enter any digit (other than “0”) in the first box to enable the zone to report.Entries in the second boxes will be ignored.FIELD TITLE and DATA ENTRIES EXPLANATION*59 Exit Error Report Code0 = no reportnon-zero = send reportIf the system is armed and an entry/exit or interior zone is still openafter the Exit Delay time has expired, an alarm will sound at thetouchpad and external sounder (touchpad also displays “EXITALARM”). If the system is disarmed before the end of the EntryDelay that immediately follows, the alarm sounding will stop and nomessage will be sent to the central station. The touchpad will display“CA” (English display touchpads) or “CANCELED ALARM” (CustomEnglish display touchpads).If the system is not disarmed before the end of the entry delaymentioned above, and an entry/exit or interior zone is still open, an“EXIT ALARM” message will be sent to the central station if an ExitError Report code is selected. The touchpad will display “EA”(English display touchpads) or “EXIT ALARM” (Custom Englishdisplay touchpads), and the alarm sounding will continue until thesystem is disarmed (or timeout occurs).An Exit Alarm condition will also result if a fault occurs in an exit orinterior zone within 2 minutes following the end of the exit delay,and an “EXIT ALARM” message will be sent to the central station.With Contact ID format, the message will contain the zone numberand error code 374 (“ALARM–EXIT ERROR”) to define the alarm asan Exit Error (rather than E/E or Interior).If “0” is entered in this field, no exit error message will be sent.