4-9FIELD TITLE and DATA ENTRIES EXPLANATION*166 Pager 3 Phone No.Enter up to 20 digitsIf you enter fewer than 20 digits, exit by pressing [∗] and next fieldnumber. To clear entries from this field, press ∗166∗.*167 Pager 3 CharactersEnter up to 16 charactersSee field ∗161 for explanation of entries. If fewer than 16 characters,exit by pressing [∗] and next field number. To clear entries from thisfield, press ∗167∗.*168 Pager 3 Reportssee pager 1 reports, field *162 for entries,except use zone list 11.Enter the types of reports to be sent to pager 3 for each partition.*169 Pager 4 Phone No.Enter up to 20 digitsIf you enter fewer than 20 digits, exit by pressing [∗] and next fieldnumber. To clear entries from this field, press ∗169∗.*170 Pager 4 CharactersEnter up to 16 charactersSee field ∗161 for explanation of entries. If fewer than 16 characters,exit by pressing [∗] and next field number. To clear entries from thisfield, press ∗170∗.*171 Pager 4 Reportssee pager 1 reports, field *162 for entries,except use zone list 12.Enter the types of reports to be sent to pager 4 for each partition.*172 Pager Delay Option for Alarms0 = none 2 = 2 minutes1 = 1 minute 3 = 3 minutesThis field determines the delay of alarm reports to the pager. Thisgives the Central Station enough time to verify the alarm report thatit received, before the dialer attempts to dial the pager.NOTE: The delay does not reset for new alarms occurring while anexisting pager delay is in progress.This delay is for ALL pagers in the system.Miscellaneous System Fields*173 RF Reporting Options1 = RF Tamper reports during disarm (1=enable, 0 = disable)2 = RF button types send low batteryreports (1= enable, 0 = disable)8 = RF low battery reports delayed (1=delayed 28 days, 0 = immediate)Example: .Entering “10” (8 + 2) will enable button-type transmittersto send low battery reports, and delay all low battery reports for 28days.*174 Clean Me Option0 = disable1 = enable3 - Clean Me reports delayed for 28 daysThis is a maintenance feature for ESL 2-wire smoke detectorson Zone 1. If used, this option limits the number of smoke detectors toa maximum of 10, rather than 16. To enable the “clean me” feature, atime response setting of “3” (1.2 seconds) must be entered in ∗56 ZoneProgramming for zone 1.*175 Up And About Time0 = none;1-15 = 1 to 15 hours respectivelyThis feature requires programming of an Up and About schedule (seeScheduling section for details). If no zones are faulted or no key ispressed within the selected time period during a scheduled Up andAbout time window, a report is sent to the central station. This canserve as a safety feature for elderly, infirm, or disabled persons.*176 Lack Of Usage Option1-15 weeksIf the control is not armed within the selected time period, a report issent to the central station.*177 Device Duration 1, 20 = 15 secs 6 = 2-1/2 min #+12 = 8 min1 = 30 secs 7 = 3 min #+13 = 10 min2 = 45 secs 8 = 4 min #+14 = 12 min3 = 60 secs 9 = 5 min #+15 = 15 min4 = 90 secs #+10 = 6 min5 = 2 min #+11 = 7 minThese entries set the duration for output action options 5 (duration1) and 6 (duration 2) programmed in ∗80 Output FunctionProgramming.*180 Single Zone Bypass0 = disable1 = enableIf enabled, users can bypass only one zone when arming the system.*181 50/60 Hz AC Operation0 = 60 Hz1 = 50 HzSelect the type of AC power applied to the control.