Safewatch Pro 3000 Installation Instructions4-6Miscellaneous System FieldsFIELD TITLE and DATA ENTRIES EXPLANATION*77 Daylight Saving TimeStart/End Month0 = Disabled # + 10 = Oct1 = Jan # + 11 = Nov2 = Feb # + 12 = Dec3 = Mar4 = AprilEnter the start and end month for daylight savings time, if applicableto the region.*78 Daylight Saving TimeStart/End Weekend0 = disabled 4 = fourth1 = first 5 = last2 = second 6 = next to last3 = third 7 = third to lastEnter the start and end weekend for daylight savings time, ifapplicable to the region.*84 Auto-Stay Arm0 = no1 = partition 1 only2 = partition 2 only3 = both partitionsWith this field enabled and system armed in AWAY mode at atouchpad (non-RF device), the system automatically reverts to armedSTAY (or INSTANT) mode if a door is not opened and shut withinthe programmed exit delay time. An Opening report followed by anArmed Stay report is sent to the Central Station. Any RF device thatarms the system AWAY overrides this feature and the systemremains armed in the AWAY mode.*85 Cross Zone Timer (in seconds)0 = 15 secs 6 = 2-1/2 min #+12 = 8 min1 = 30 secs 7 = 3 min #+13 = 10 min2 = 45 secs 8 = 4 min #+14 = 12 min3 = 60 secs 9 = 5 min #+15 = 15 min4 = 90 secs #+10 = 6 min5 = 2 min #+11 = 7 minSets the maximum amount of time in which two cross zones must betripped in an armed system to send an Alarm message to the CentralStation. If only one cross zone is tripped during this time, a Troublemessage (report) is sent to the Central Station.Assign cross zone pairs in zone list 4.This option not for use in UL installations.*86 Cancel Verify0 = no1 = yesWhen enabled (1 = yes), this feature causes the message“CANCELED ALARM” to be displayed on the LCD keypad underthe following conditions:• After the kissoff of the cancel message to the Central Station,indicating a successful transmission.• When an alarm is successfully canceled before the Central Stationreceived the Alarm message. For example, if an alarm isincorrectly triggered and the user presses code + OFF before thedial delay time for the alarm has expired, the message will nevergo out to the CS.• When the Cancel report is not enabled and the system is disarmed:a. before dialer delay expires (alarm report not sent) message“Canceled Alarm” is displayed.b. after dialer delay expires message “Canceled Alarm” is notdisplayed.*89 Event Log Full Report Code0 = no report1st digit non-zero = send reportIf an Event Logging selection is made in field ∗90, a message can besent to the central station receiver when the log is 80% full. If the logbecomes full, new messages overwrite the oldest messages in the log.*90 Event Logging0 = no event logging1 = log Alarm/Alarm Restore2 = log Trouble/Trouble Restore4 = log Bypass/Bypass Restore8 = log Open/Closex = log combination of events (add value ofentries)This system has the ability to record various events in a history log(up to 100 events). At any time, the downloader operator can thenupload the log and view or print out all or selected categories of thelog. The log can also be cleared by the downloader operator.The display/printout at the central station will show the date, time,event, and description of the occurrences.Data Entry Example: To select Alarm/Alarm Restore” and“Open/Close”, enter 9 (1+ 8); to select all events, enter #15.