6-1S E C T I O N 6Output Device Programming(*79/*80 Menu Mode)• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •About Output Device ProgrammingOutput Devices: The system supports up to 16 relays and/or Powerline Carrier devices (X-10devices) plus 2 built-in trigger outputs in any combination. These 18 “outputs”are assigned to system-wide output numbers (01-18). Use *79 Menu Mode toassign output numbers and map them to device addresses.Output Functions: The system also provides up to 48 installer-defined output functions, which canbe assigned to any of the 18 physical outputs. Therefore, the action of any oneof the 18 outputs can be based on as many of these functions as desired. Thislets a single relay or X-10 device perform many functions. Use *80 Menu Modeto define output functions.Relays and output devices are not recommended for life safety applications.NOTE: When navigating the *79 and *80 menus: The [Q] key is used to accept an entry and advanceto the next prompt. The [#] key is used to revert back to the last question to check or change anentry. Press [Q] to go forward again.Output Device programming involves:1. Use *79 Menu Mode to assign module and output numbers and map them to device addresses.NOTE: You must map output devices using *79 Menu Mode before you can use *80 menu Mode).2. Use *80 Menu Mode to create up to 48 output definitions, which control the output devices.*79 Menu Mode: Output Device MappingUse this menu to assign Relay Module device addresses and specific relay numbers, and PowerlineCarrier unit numbers. The system is based on predefined module addresses for 4204 and 4229modules. Refer to the table shown at the “Module Address” prompt on the next page and set themodules’ addresses (via module DIP switches) accordingly.The following table shows how these outputs are identified.Output IdentificationThis output… is identified by…Relays: the Relay Module’s device address and the relay position on that module (i.e. thephysical relay number, 1-4, on that module).X-10 Device a house ID (entered in data field *27) and the unit number of the device.Built-in Outputs the output number assigned, 17 for trigger 1 and/or 18 for trigger 2.