10-1S E C T I O N 1 0Creating Schedules• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •About SchedulesThe system provides up to 32 schedules, which can be used to control up to 12 types of system events atpre-defined times. Sixteen schedules are intended for use by the end-user, and sixteen are reserved forthe installer. In addition, some events are also reserved for the installer only (listed in the “EnterEvent” prompt paragraph below).Start Scheduling mode by entering installer code + [#] + [6] [4] while in normal operating mode.The following prompts are displayed:PROMPT VALID ENTRIES EXPLANATIONE N T E R S C H E D N O .0 0 = Q U I T 0 0Schedule Number01-16 = end-user schedules17-32 = installer-only schedules[∗] to continueSchedule numbers 01-16 can be programmed and changed by the enduser or installer. Schedules 17-32 can only be programmed orchanged by the installer.E N T E R E V E N T Enter Event00 = clear event01 = Relay On/Off02 = User Access03 = Latch Key Report to Pager04 = Forced Stay Arming†05 = Forced Away Arming†06 = Auto Disarm07 = Display “Reminder”10 = Display custom words ††11 = Periodic Test Report12 = Up and About †††[∗] to continueEnter the desired event number for event you want to occur at aspecified time.Events 10-12 are reserved for the installer only.Latch key report (option 03) is sent to all pagers in the user’spartition. User must be enabled for paging (see User Attributes inSystem Operation section).† Forced bypass must be enabled in field *23.†† if selected, system displays custom words 8, 9, and 10 at definedtime. Can be used as installer’s reminder message to the end user.†††This selection defines the large time window within which thetime window selected in data field *175 will be monitored.D E V I C E N U M B E RX XDevice Number01-18 = device number[∗] to continueThis prompt appears if event “1” (relay on/off) was selected, otherwiseit is skipped.Enter the physical device number as programmed in ∗79 Menu Mode,then press [*] to continue to the “Start” prompt.Device numbers 17 and 18 designate built-in triggers 1 and 2respectively.G R O U P N U M B E RXGroup Number01-8 = group number[∗] to continueThis prompt appears if event “2” (user access) was selected.Otherwise it is skipped.Press [*] to continue to the “Start” prompt.P A R T I T I O NX XPartition0 = all partitions1 = partition 12 = partition 23 = common[∗] to continueThis prompt appears if events “3-7,10,12” were selected. Otherwise itis skipped.Press [*] to continue to the “Start” prompt.S T A R T S M T W T F SH H M M A M 0 0 1 0 0 0 0Start Time01-12 = hour00-59 = minute0 = AM; 1 = PMDays = place “1” under days[∗] to continueEnter the event’s start time and days of the week to occur.To select days, position the cursor under the desired days using the[∗] key to move forward, then press “1” to select the day.