13-1S E C T I O N 1 3Testing the System• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •About Test ProceduresAfter the installation is complete, you should perform the following tests:System Test: Checks that all zones have been installed properly and the system properlyresponds to faults.Dialer Test: Checks that the phone connection to the central station is working properly.Go/No Go Test: Checks that transmissions can be received from transmitters. Should beperformed before permanently mounting transmitters.RF Sniffer Mode: Checks that RF transmitter serial numbers have been properly entered into thesystem.Battery Tests: Automatic battery tests are performed by the system. See Automatic Battery Testparagraph for details.System TestWith the system in the disarmed state, check that all zones are intact (not faulted). Doors andwindows with contacts should be closed, PIRs should be covered (use a cloth to mask themtemporarily if necessary). If a “NOT READY” message is displayed, press [∗] to display the faultedzone(s). Restore faulted zone(s) if necessary, so that the “READY” message is displayed.1. Enter Installer Code + 5 [ TEST ] , then press “0” at the prompt to start Walk Test mode.1=DIAL, 0=WALKThe following will be displayed:TEST IN PROGRESS (“dd” displayed on English Display Touchpads)A Contact ID report will also be sent (code 607)2. Upon entering the system test mode, the outside sounder should sound for 1 second.If the backup battery is discharged or missing, the sounder may not turn on and a “LOWBATTERY” report will be transmitted with a “TEST” report.The touchpad will beep once per minute as a reminder that the system is in the Test mode.NOTE: Wireless motion detectors (Passive Infrared units) will send signals out only if they havebeen inactive for 3 minutes (conserves battery life).3. Test all sensors using the procedure described in the User’s Guide “Testing the System” section.4. After checking sensors, turn off the test mode by entering installer code + OFF.NOTE: Test mode automatically ends after 4 hours.