Standard Features AW00097603000256 Basler aviator GigE10.19.1 Selecting a Factory Setup as the Default SetWhen the camera is delivered, the Standard Factory Setup will be selected as the default set. Youcan, however, select any one of the four factory setups to serve as the default set.To select which factory setup will serve as the default set using Basler pylon:Set the Default Set Selector to the Standard Factory Setup, High Gain Factory Setup, AutoFunctions Factory Setup or Color Factory Setup.You can set the Default Set Selector from within your application software by using the pylon API.The following code snippet illustrates using the API to set the selector:If you want to select the Standard Factory Setup:Camera.DefaultSetSelector.SetValue(DefaultSetSelector_Standard);If you want to select the High Gain Factory Setup:Camera.DefaultSetSelector.SetValue(DefaultSetSelector_HighGain);If you want to select the Auto Functions Factory Setup:Camera.DefaultSetSelector.SetValue(DefaultSetSelector_AutoFunctions);If you want to select the Color Factory Setup:Camera.DefaultSetSelector.SetValue(DefaultSetSelector_Color);For more information about the pylon API and the pylon Viewer, see Section 3 on page 21.Selecting which factory setup will serve as the default set is only allowed when thecamera is idle, i.e. when it is not acquiring images continuously or does not havea single image acquisition pending.Selecting the standard factory setup as the default set and then loading the defaultset into the active set is a good course of action if you have grossly misadjustedthe settings in the camera and you are not sure how to recover. The standardfactory setup is optimized for use in typical situations and will provide good cameraperformance in most cases.