Configuring the CameraBasler sprint Mono Cameras 161Camera Status InquiryThe camera has been programmed to detect several error conditions. When an error condition isdetected, a flag is set. The camera status inquiry register allows you to read the error flags.Register Base Address: 0x0C00Field Name: Register Status Offset: 0x0000 Size: 1 Byte Type: Read onlyDescription: The integer value in this field indicates the status of this inquiry register:0x00 = The register is not available0x01 = The register is availableField Name: Camera Status Offset: 0x0001 Size: 4 Bytes Type: Read onlyDescription: Each bit in this field specifies an error condition (see table below). Bit 0 is the least significant bit.If a bit is set to 1, the error condition assigned to that bit is present. If the bit is set to 0, the error isnot present.Bit Description0 Reserved1 The camera is busy performing an internal operation (such as generating shadingvalues).2 A reset has occurred.3 Parameter error. For example, a parameter has been set to a value that is out of rangeor not allowed.4 A user set load has failed.5 A file operation has failed.6 A camera power overvoltage condition is present (see Section 6.9.2 on page 147).7 A binary read/write command protocol error has been detected. For more informationabout the error, read the Binary Command Protocol Status Inquiry Register (seepage 163). This bit is auto-cleared on read.8 ... 15 Reserved16 An FPGA not ready error has occurred. For more information about the error, read theFPGA Status Inquiry register (see page 162). This bit clears when you read the FPGAStatus Inquiry register.17 A trigger error has occurred. Either the maximum allowed line rate has been exceededor the ExSync signal is missing. For more information about the error, read the FPGAStatus Inquiry register (see page 162). This bit clears when you read the FPGA Statusinquiry register.18 Reserved19 The last shading value generation process failed.The DSNU shading value generation process can fail if the pixel values in the linescaptured during the generation process are too high. (This process should beperformed in darkness or in very low light conditions.)The PRNU shading value generation process can fail if the values for the darkestpixels in the captured lines are less than 1/2 of the values for the highest pixels, Thisproblem is often caused by extremely non-uniform lighting or by poor quality optics.This bit will clear when you perform a successful shading value generation process.20 An overtemperature condition is present (see Section 6.9.1 on page 146).21 ... 31 Reserved