Configuring the CameraBasler sprint Mono Cameras 195Shading Values CSRSee Section 7.2.3.2 on page 190 for information about using the shading values bulk data controlregisters.Register Base Address: 0x2A00Field Name: Register Status Offset: 0x0000 Size: 1 Byte Type: Read onlyDescription: The integer value in this field indicates the status of this control and status register:0x00 = The register is not available0x01 = The register is available and all related settings are OK0x80 = A value in the register is set out of rangeField Name: Control Offset: 0x0001 Size: 1 Byte Type: Read/WriteDescription: Writing an integer to this field selects a bulk data control function:0x00 = Enumerate0x01 = ENext0x02 = Read0x03 = Write0x04 = Erase0x05 = Activate0x06 = CopyField Name: Info Offset: 0x0002 Size: 1 Byte Type: Read onlyDescription: If you are performing a bulk read or write operation, this field will indicate when no more dataexists:0x00 = More data exists0x01 = No more data exists0x02 = File operation error0x04 = This is an activated fileField Name: File Name Offset: 0x0003 Size: 20 Bytes Type: Read/WriteDescription: Character string indicating the name of the bulk data file. The field contains 20 characters (leftaligned and zero padded). Only the following names are allowed: FactoryShading, UserShading.Field Name: Size Offset: 0x0017 Size: 4 Bytes Type: Read onlyDescription: If the file name refers to an already existing bulk data file, this field will contain the file size inbytes. Otherwise, the field contains zeros.Field Name: Data Offset: 0x001B Size: Variable Type: Read/WriteDescription: Byte sized register that is used to sequentially write to or read from a bulk data file.