Chapter 33-14- Be sure not to disassemble the laser / scanner unit as it needs adjustment.- When holding the laser / scanner unit, be sure not to touch the laser mountblock [1] and the lens block [2].F-3-973.3 IMAGE FORMATION SYSTEM3.3.1 Developing Estrangement Solenoid3.3.1.1 Preparation for Removing the DevelopingEstrangement Solenoid 0014-4824/ i-SENSYS LBP5360 / i-SENSYS LBP53001) Detach the rear cover. (page 3-1)[Removing the Rear Cover]2) Remove the fixing assembly. (page 3-25)[Removing the FixingAssembly]3) Detach the upper cover. (page 3-2)[Removing the Upper Cover]4) Detach the right cover. (page 3-1)[Removing the Right Cover]3.3.1.2 Removing the Developing Estrangement Solenoid0014-4826/ i-SENSYS LBP5360 / i-SENSYS LBP53001) Remove the claw [2] and move the cable guide [1] to the left.F-3-982) Remove the plate [1].- 3 screws [2]F-3-993) Disconnect the 2 connectors and free the cable from the wire saddle [1].F-3-1004) Remove the developing estrangement drive unit [1].- 3 screws [2]F-3-1015) Detach the sheet metal [1].- 3 screws [2]F-3-1026) Remove the developing estrangement solenoid [1].- 2 screws [2]F-3-1033.3.1.3 Points to Note when Attaching the DevelopingEstrangement Solenoid 0014-8848/ i-SENSYS LBP5360 / i-SENSYS LBP5300Alignment of Developing Estrangement Drive Unit1. Alignment of Developing Estrangement Drive Unit in AssemblingRotate the gear [2] of the developing estrangement drive unit[1] to thedirection of the arrow, and align the solenoid claw [3] with the positionof the cut-off in the gear (home position).