Chapter 33-23F-3-16712) Place the right side of the host machine downward, move the base plate[1] approx. 30 mm from the pick-up drive assembly [2].F-3-16813) Remove the pick-up drive assembly [1].- 2 screws [2]F-3-16914) Detach the plate [1].- 4 screws [2]F-3-17015) Remove the manual feed pick-up solenoid [1].- 1 screw [2]F-3-1713.4.8 Manual Separation Pad3.4.8.1 Preparation for Removing the Manual FeedSeparation Pad 0014-8835/ i-SENSYS LBP5360 / i-SENSYS LBP53001) Remove the ETB unit. (page 3-15)[Removing the ETB Unit]3.4.8.2 Removing the Manual Feed Separation Pad 0013-9993/ i-SENSYS LBP5360 / i-SENSYS LBP53001) Remove the manual feed separation pad [1].- 1 screw [2]F-3-1723.4.9 Duplexing Reverse Motor3.4.9.1 Preparation for Removing the DuplexingReversing Motor 0014-4840/ i-SENSYS LBP5360 / i-SENSYS LBP53001) Detach the rear cover. (page 3-1)[Removing the Rear Cover]2) Remove the fixing assembly. (page 3-25)[Removing the FixingAssembly]3) Detach the upper cover. (page 3-2)[Removing the Upper Cover]4) Detach the duplexing driver PCB. (page 3-10)[Removing the DuplexingDriver PCB]3.4.9.2 Removing the Duplexing Reversing Motor 0014-4846/ i-SENSYS LBP5360 / i-SENSYS LBP53001) Free the claw [1] of the bushing.F-3-1732) Turn the bushing [1] to pull it out in the direction of the arrow.