IDL-MODE Use it to select idle rotation mode for the developing assembly.0: fix to low humidity mode (off)1: environment control (default)2: fix to normal temperature/humidity mode (idle rotation for 120sec)3: fix to high humidity mode (idle rotation for 300 sec)4: power save mode2FSPD-S1 Use it to select fixing enhancement mode.0: normal (default)1: fixing enhancement mode2: not used2TSPLY-SW Use it to switch over toner supply sequence.0: environment control (default)1: fix to low humidity mode (on for 1.4 sec, off for 1 sec)2: fix to normal temperature/humidity mode (on for 1.5 sec, offfor 1 sec)3: fix to high humidity mode (on for 3 sec, off for 2 sec)2SCANSLCT Use it to enable/disable the function used to compute the scan areafrom the selected paper size.setting0: off (determine scan area by original detection)1: on (determine scan area by paper size)2OHP-TEMP Use it to switch over control temperature for transparency mode.setting0: normal (default); 1: -5 deg C; 2: -10 deg C; 3: -15 deg C; 4: -20deg C2SENS-CNF Use it to set the arrangement of original sensors.setting0: AB (default)1: inch2: A2RAW-DATA Use it to specify how received data should be printed.If a received image has a fault, use this mode to find out if the faultis in the data or in image processing.setting0: normal operation (default)1: print as is2SHARP Use it to change the level of sharpness (median value).setting: 1 to 5 2COPIER > OPTION > BODYSub-item Description Level