MCO 305 Design Guide__ APOSS Tools __MG.33.L5.02 – VLT® is a registered Danfoss trademark 155Poll RateThe poll rate specifies how often the Oscilloscope will try to read data for polled curves from the controllerwhen an Oscilloscope “run” start been started. Care should be taken not to set this time shorter thannecessary as it can significantly increase demands on the PC processor, the controller processor, and thecommunication network.Sample CountThis is the default sample count to be used when new curves are added. The sample count is the maximumnumber of points that the Oscilloscope will save for a curve before old points are discarded to make roomfor new points. See also Properties → Source.Event Time / Inhibit TimeThis is the default PDO event time and the default PDO inhibit time to be used when new curves are beingadded.After a curve has been added, these values can be changed by using Properties → Source in the “CurveSelection List”.Default Test ConfigurationThis set of parameters specifies the default values to be used by the Tune Oscilloscope.