MCO 305 Design Guide__ Parameter Reference __¾ default setting [ ] value for use in communication via serial communication port238 MG.33.L5.02 – VLT® is a registered Danfoss trademark33-94 X60 MCO RS485 Serial terminationRSTERMINATIONOption¾ Off [0]On [1]FunctionChoose termination for the RS485 connection onX60.33-95 X60 MCO RS485 serial baud rateRSBAUDRATEOption2400 Baud [0]4800 Baud [1]¾ 9600 Baud [2]19200 Baud [3]38400 Baud [4]57600 Baud [5]76800 Baud [6]115200 Baud [7]FunctionDefines the baud rate of the MCO RS485 serial link. MCO Data ReadoutsTo support the PCD[] array reading and writing andstill be in accordance with the ProfiDrive profilethere are the following 20 parameters in the 34-0*and 34-2* group: 34-0* PCD Write Parameters34-01...10 PCD n Write to MCOn = 1 – 10p. 34-01 = PCD 1 Write to MCOp. 34-02 = PCD 2 Write to MCOp. 34-03 = PCD 3 Write to MCOp. 34-04 = PCD 4 Write to MCOp. 34-05 = PCD 5 Write to MCOp. 34-06 = PCD 6 Write to MCOp. 34-07 = PCD 7 Write to MCOp. 34-08 = PCD 8 Write to MCOp. 34-09 = PCD 9 Write to MCOp. 34-10 = PCD 10 Write to MCOFunctionAll 10 parameters are selectable as display lineparameters in par. 0-20 to 0-24.But at index [n] only MCO PCD[n] Write can beselected. This selection defines that correspondingsub indices will be consumed by the MCO 305.This also makes it possible to set the indices 0 and1 (CTW/STW and REF/MAV) to MCO. This mighthowever be in conflict with the ProfiDrive profile.