P710 P800 P900High/normal load* HO NO HO NO HO NOTypical shaft output at 550 V [kW] 500 560 560 670 670 750Typical shaft output at 575 V [hp] 650 750 750 950 950 1050Typical shaft output at 690 V [kW] 630 710 710 800 800 900Enclosure IP21/IP54 with/without options cabinet F1/F3Output currentContinuous (at 550 V) [A] 659 763 763 889 889 988Intermittent (60 s overload) (at 550 V)[A] 989 839 1145 978 1334 1087Continuous (at 575/690 V) [A] 630 730 730 850 850 945Intermittent (60 s overload) (at 575/690 V) [kVA] 945 803 1095 935 1275 1040Continuous kVA (at 550 V) [kVA] 628 727 727 847 847 941Continuous kVA (at 575 V) [kVA] 627 727 727 847 847 941Continuous kVA (at 690 V) [kVA] 753 872 872 1016 1016 1129Max. input currentContinuous (at 550 V) [A] 642 743 743 866 866 962Continuous (at 575 V) [A] 613 711 711 828 828 920Continuous (at 690 V) [A] 613 711 711 828 828 920Max. cable sizeMotor (mm2/AWG2) ) 8x150 (8x300 mcm)Mains, F1 (mm2/AWG2) ) 8x240 (8x500 mcm)Mains, F3 (mm2/AWG2) ) 8x456 (8x900 mcm)Loadshare (mm2/AWG2)) 4x120 (4x250 mcm)Brake (mm2/AWG2)) 4x185 (4x350 mcm)Max. external mains fuses [A] 1600Estimated power loss at 575 V [W]3) 8075 9500 9165 10872 10860 12316Estimated power loss at 690 V [W]3) 8388 9863 9537 11304 11291 12798Max. added losses CB or disconnect and contactor,F1/F3342 427 419 532 519 615Max. panel option losses 400Weight, enclosure IP21, kg [lbs.] 1017/1318 [2242/2905]Weight, enclosure IP54, kg [lbs.]Weight, rectifier module, kg [lbs.] 102 [224]Weight, inverter module, kg [lbs.] 102 [224] 136 [299]Efficiency4) 0.98Output frequency [Hz] 0-500Heatsink overtemp. trip [°C] 95 105 95Power card ambient trip [°C] 85*High overload=150% current for 60 s, Normal overload=110% current for 60 s.Table 8.8 Technical Specifications, F1/F3, Mains Supply 3x525-690 V ACGeneral Specifications and ... Design GuideMG20Z202 Danfoss A/S © Rev. 06/2014 All rights reserved. 1738 8