P1M0 P1M2 P1M4High/normal load* HO NO HO NO HO NOTypical shaft output at 550 V [kW] 750 850 850 1000 1000 1100Typical shaft output at 575 V [hp] 1050 1150 1150 1350 1350 1550Typical shaft output at 690 V [kW] 900 1000 1000 1200 1200 1400Enclosure IP21, IP54 without/with options cabinet F12/F13Output currentContinuous (at 550 V) [A] 988 1108 1108 1317 1317 1479Intermittent (60 s overload) (at 550 V)[A] 1482 1219 1662 1449 1976 1627Continuous (at 575/690 V) [A] 945 1060 1060 1260 1260 1415Intermittent (60 s overload) (at 575/690 V) [kVA] 1418 1166 1590 1386 1890 1557Continuous kVA (at 550 V) [kVA] 941 1056 1056 1255 1255 1409Continuous kVA (at 575 V) [kVA] 941 1056 1056 1255 1255 1409Continuous kVA (at 690 V) [kVA] 1129 1267 1267 1506 1506 1691Max. input currentContinuous (at 550 V) [A] 962 1079 1079 1282 1282 1440Continuous (at 575 V) [A] 920 1032 1032 1227 1227 1378Continuous (at 690 V) [A] 920 1032 1032 1227 1227 1378Max. cable sizeMains (mm2 / AWG2)) 12x150 (12x300 mcm)Motor (mm2 / AWG2)) 8x400 (8x900 mcm)Brake (mm2 / AWG2)) 6x185 (6x350 mcm)Max. external mains fuses [A] 1600 2000 2500Estimated power loss at 600 V [W]3) 12062 13731 13269 16190 16089 18536Estimated power loss at 690 V [W]3) 12524 14250 13801 16821 16719 19247F12/F13 max. added losses A1 RFI or disconnect 556 665 634 863 861 1044Max. panel options losses 400Weight, enclosure IP21, kg [lbs.] 1260/1561 [2778/3441] 1294/1595 [2853/3516]Weight, enclosure IP54, kg [lbs.]Weight, rectifier module, kg [lbs.] 136 [300]Weight, inverter module, kg [lbs.] 102 [225] 136 [300]Efficiency4) 0.98Output frequency [Hz] 0–500Heatsink overtemp. trip [°C] 95 105 95Power card ambient trip [°C] 85*High overload=150% current for 60 s, Normal overload=110% current for 60 s.Table 8.15 Technical Specifications F12/F13 12-Pulse, Mains Supply 6x525-690 V AC1) For type of fuse, consult the Operating Instructions2) American Wire Gauge3) The typical power loss is at normal conditions and expected to be within ± 15% (tolerance relates to variety in voltage and cable conditions.)These values are based on a typical motor efficiency (eff2/eff3 border line). Lower efficiency motors add to the power loss in the frequencyconverter and the opposite is also true. If the switching frequency is raised from nominal, the power losses rise significantly. LCP and typicalcontrol card power consumptions are included. Further options and customer load can add up to 30 W to the losses (though typically only 4 Wextra for a fully loaded control card or options for slot A or slot B, each)4) Measured using 5 m screened motor cables at rated load and rated frequencyGeneral Specifications and ... Design GuideMG20Z202 Danfoss A/S © Rev. 06/2014 All rights reserved. 1798 8