Management | 71When the S50 starts to reload, the following text appears at the console:Figure 4-44. Rebooting2. When the text above appears, you have two seconds to enter 2 (as shown) and then press Enter. If youare not fast enough, the router will boot normally.If you are successful, the following menu appears:Figure 4-45. Boot Menu3. Select option 9 to delete the current configuration, including any admin and enable passwords.4. Select option 8 to restart the system. When the S50 finishes rebooting, you can configure the routerfrom scratch.For other methods of managing running-config and system-config files, see Managing the Configurationon page 56.Setting up SNMP ManagementSimple Network Management Protocol (SNMP) communicates management information betweenSNMP-based network management stations and SNMP agents in the switch. S-Series systems supportSNMP versions 1, 2c, and 3, supporting both read-only and read-write modes. SFTOS sends SNMP traps,which are messages informing network management stations about the network.SFTOS supports up to six simultaneous SNMP trap receivers. SFTOS does not support SNMP on VLANs.Reloading all switches.Force10 Boot Code...Version 01.00.26 06/03/2005Select an option. If no selection in 2 seconds then operational code will start.1 - Start operational code.2 - Start Boot Menu.Select (1, 2):2Boot Menu Version: 30 Aug 2006Options available1 - Start operational code2 - Change baud rate3 - Retrieve event log using XMODEM (64KB).4 - Load new operational code using XMODEM5 - Display operational code vital product data6 - Run flash diagnostics7 - Update boot code8 - Delete operational code9 - Reset the system10 - Restore configuration to factory defaults (delete config files)11 - Activate Backup Image[Boot Menu]