Table 33: Component LEDs on the J-SRX240 Services Gateway (continued)Possible Causes and CorrectiveActionsMeaningStateLEDNormal condition. No action isrequired.The device is receiving power supplyand is functioning normally.GreenPower LEDNormal condition. No action isrequired.The Power button has been pressedand quickly released. The device isgracefully shutting down or startingup.AmberNormal condition if the servicesgateway is switched off. No action isrequired.If you have not powered off theservices gateway, verify that the ACpower cord from the power sourceto the device is not damaged, thesocket is in working condition, andthe device has an AC input voltagebetween 110 and 240 VAC. See“Monitoring the J-SRX240 ServicesGateway Power System” on page 93.The device is not receiving power.OffThe device is not part of the chassiscluster setup.OffHA LEDNormal condition. No action isrequired.The Mini-PIM is present and detectedby the device.GreenMini-PIM LEDSee “Monitoring the J-SRX240Services Gateway Using ChassisAlarm Conditions” on page 92.The Mini-PIM is not present or is notdetected by the device.Off90PowerConnect J-SRX240 Services Gateway Hardware Guide