Part NumberIssueDatePage61599388801301/2018161 / 249161 (249) 01/2018For quickstep or two-step nutrunners, the 2nd threshold is used to exclude the first step from themeasurement; if not set properly, the peak of the first step is considered as result of the test:13.1.3.2 Last peakThis option is used mainly to detect the last peak of the tightening even if this is lower than themaximum peak:A typical scenario can be represented by the search of the last torque in self-tapping or specialscrews, where the last torque peak is considered the torque applied to the joint.Max. torqueTimeTorqueTorque ResultThe 2nd threshold mustbe higher than the peakof the first stepFirst step Second stepMax. torque2nd thresholdTime1st thresholdTorque