Part NumberIssueDatePage61599388801301/2018194 / 24901/2018 194 (249)20.1.1.5 Enabling the results via Ethernet20.1.1.6 Enabling the SIMAP-BoxResults viaEthernetBy enabling this option, the Delta sends the test results for tool testing viaEthernet.The results are exported in the following format:ZZZZ GG/MM/YY HH:mm:ss torque angle S\r\nWhere:- ZZZZ Counter, starting from 0001 and incremented after eachresult; it is reset when the test execution window is quit- GG/MM/YY Date (day/month/year)- HH:mm:ss Time (hours:minutes:seconds)- torque Torque result- angle Angle result- S Status: A if result is OK, R if Not OK- \r Carriage return- \n Line feedNOTE: Between torque, angle and status there are four space; if the angleis not included in the tightening, the angle filed and the four spaces are notpresent in the message.NOTE: By enabling the Results via Ethernet option, the SIMAP-Boxfunction is automatically disabled.SIMAP-BoxBy enabling this option, the Delta sends the test results for tool testing to theSIMAP-Box by means of the serial port.The results are exported in the following format:ZZZZ GG/MM/YY HH:mm:ss torque angle S\r\nWhere:- ZZZZ Counter, starting from 0001 and incremented after eachresult; it is reset when the test execution window is quit- GG/MM/YY Date (day/month/year)- HH:mm:ss Time (hours:minutes:seconds)- torque Torque result- angle Angle result- S Status: A if result is OK, R if Not OK- \r Carriage return- \n Line feedNOTE: Between torque, angle and status there are four space; if the angleis not included in the tightening, the angle filed and the four spaces are notpresent in the message.NOTE: By enabling the SIMAP-Box option, the Results via Ethernetfunction is automatically disabled.NOTE: By enabling the SIMAP-Box option, the serial port is no moreavailable for the CVI II Calibration function; to calibrate the CVI II, theSIMAP-Box must be disabled