Part NumberIssueDatePage61599388801301/2018186 / 24901/2018 186 (249)19.1 Torque TimeTorque Time strategy leads theoperator in reaching the desired targettorque, without any angle reading.It is enough to define the Cycle start,Minimum Torque, Target Torque andMaximum Torque, and the ChangeScrew at.The “green area” identifies the OK result area.If the torque goes over the “change screw” value, a message is shown on the Delta display in order toadvise the operator to replace the screw.The torque result is the maximum torque measured during the tightening.The Delta torque LEDs are activated as follows:Low (yellow) LED Torque lower than the minimum value.OK (green) LED Torque within the minimum torque and maximum torque.High (red) LED Torque over the maximum torque.The buzzer is activated as follows:Buzzer The beep emitted by the buzzer starts when the torque goes over theCycle Start value, and it increases its signal when approaching thetarget.At the end of the tightening operation three more beeps inform theoperator of the end of the operation; if the torque goes over themaximum values, the beep is repeated at high frequency to indicate theerror.Max. TorqueTorqueCycle startMin. TorqueTarget TorqueTimeChange screw at