Part NumberIssueDatePage61599388801301/2018177 / 249177 (249) 01/201817.1 Residual Torque/Angle“Residual Torque/Angle” strategyevaluates the residual torque on a joint,by measuring the Torque at the targetangle.The target angle is set to few degrees, inorder to detect the point where the boltstarts moving.Define the torque limits for considering as OK the test result.The Angle Threshold, which must be greater than the Cycle start, defines the point from which theangle measurement starts. The Delta measures the torque at the Target angle.At the end of the test, the Delta display shows the breakaway point and also the torque peak valuereached during the test; the breakaway point is normally lower than the peak value.If the operator goes over the Change Screw value during the residual torque check, a message isshown on the display to indicate that the screw must be replaced with a new one.The LEDs are activated as follows:Low (yellow) LED Torque result below the minimum torque.OK (green) LED Torque result within the limits.High (red) LED Torque result over the maximum torque.The buzzer is activated as follows:Buzzer High tone is emitted if test gives OK result (torque withinthe limits); if not, a low tone is emitted.NOTE: The LEDs and buzzer are activated at the end of the tests.Cycle startTorque min.Torque max.TorqueAngleTarget angleAngle threshold