Part NumberIssueDatePage61599388801301/2018165 / 249165 (249) 01/2018The LEDs are activated as follows:OK (green) LED Delta 1D: Peak value not exceeding the maximum transducer overload.Torque status is marked as OK.Delta 6D/7D: Peak within the limits. Torque status is marked as OK.Low (yellow) LED Torque detected below the minimum torque.High (red) LED The following results give a Not OK result:- Torque over the transducer overload- Torque out from the limits (not for Delta 1D)- Torque status is marked as Not OKThe buzzer is activated as follows:Buzzer High tone when green led is activated; otherwise, lower tone.14.1 Test Setup for Pulse Tool Test For Delta 6D/7D, all of the parameters described in this paragraph are stored inside the Pset. Seebelow for more information about the specific parameters of the Pulse Tool test and refer to theparagraph “Pset” for further details about the Pset.For the Quick Test mode, the function is the same of the Delta 1D described below. For Delta 1D (and Delta 6D/7D) Quick Test, all of the parameters described in this paragraphare entered directly on the Delta menu, by selecting Measurement Setup → Tools setup →Pulse Tool menu:Delta 1D – Quick Test Setup