Part NumberIssueDatePage61599388801301/2018188 / 24901/2018 188 (249)The buzzer is activated as follows:Buzzer The beep emitted by the buzzer starts when the torque goes over theCycle Start value, and it increases its signal when approaching thetarget.At the end of the tightening operation three more beeps inform theoperator of the end of the operation; if the torque goes over themaximum values, the beep is repeated at high frequency to indicate theerror.19.3 Torque + AngleTorque + Angle strategy leads theoperator in reaching the desired targetangle from a specified torque value.This strategy is similar to Torque &Angle strategy (refer to the paragraph“Torque & Angle” for further details);the Target Angle value is requiredinstead of the Target Torque, and theprogressive bar increases with theangle and not with the torque.If the torque goes over the “changescrew” value, a message is shown onthe Delta display in order to advise theoperator to replace the screw.The Torque/Angle results may be as follows:- If the torque/angle does not exceed the torque/angle limits, the result is taken at the torque peakor angle peak as specified in the Pset options.- If the torque/angle goes over the limit, the result is taken as follows:Angle peak Angle peakTorque peak selected in the Pset Angle peak selected in the PsetTorque peak Torque peakTorqueMin. TorqueTargetAngleMax. TorqueMin. Angle Max. AngleCycle startAngle thresholdAngleChange screw at