Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Introduction
- Applicability
- Power Xpert Software Subscription
- AC Power Measurement Concepts Used in this Manual
- Feature Comparison between Power Xpert Meter Models
- Warranties
- Quick Start Guide for the Meter Module
- Power Supply Connections
- VT , VX & CT Connections
- Establishing Communications between the Meter Module and the Optional Graphic Display Module
- Operating the Display Module
- Programming the Meter Module using the Embedded Web Server Interface
- Programming the Meter Module via the Optional Communications Expansion Card
- Installation
- Mounting the Power Xpert Meter and Display Separately
- Wiring of CT & VT Connections
- CT & VT Connector Installation on the Power Xpert
- MeterDimensions
- WIRING
- Communication Wiring
- RS485 Network
- LEDs
- Display Link Addressing
- Introduction to Web Server Screens
- Home, Meter, Power, Quality, Energy, I/O, Events & Setup Screens
- The Meter Main Screen
- The Power Main Screen
- The Energy Main Screen
- Selecting Other Devices From The Events Screen
- I/O Screen
- Introduction to the Local Graphical Display
- The Main Screens
- Navigating from one Main Screen to another
- Accessing Details From All Main Screens
- The Events Main Screen
- The Setup Main Screen
- Functions on the Web Server
- Functions on the Graphical Display
- Meter
- Energy
- Quality
- Subcycle Disturbance
- Setup on the Web Server
- Setup on the Graphical Display
- Quick Setup
- Meter Setup and Commissioning
- Setup" This Display (Screen contrast, etc.)
- Network, Firmware & Product Information
- Password Setup
- Firmware Upgrade
- Upgrading From a PXM4000 to a PXM6000
- Troubleshooting & Maintenance
- Return Procedure
- Operating in Safe Mode
- Glossary
- A MODBUS Communication
- A.5. Register 2901 (Controls – Modbus RTU)
- A.8. Register 4609 (Product Status)
- A.10. Registers 4611-6332 (Real-Time Measured Values)
- B Standard & Extended Modbus Register Maps
- B.2. Extended Modbus Register Map
- B.3. Minimum and Maximum Register Map
- B.4. I/O Register Map
- B.5. Appendix E – Event Trigger Register Map
- B.6. Event Log Register Map
- B.7 . Trend and Profile Query Register Map
- B.8. Latest Min/Max/Avg Register Map
- B.9. Latest Demand Profile Register Map
- C SNMP Communication
- D Diagnostics
- D.1. Battery Status
- D.2. System Log
- D.3. Event Count
- D.4. Communications - Ethernet Status
- D.6. Communications - COM0, COM1, COM2, COM3 (Slave)
- D.7 . Communications - COM1, COM2, COM3 (Master)
- D.8. Communications - I/O Internal Input Status
- E Option Cards
- E.1. Power Xpert Meter Option Cards
- E.2. Optional I/O Card
- E.3. 1ms Time Stamping of Digital and Sub-Cycle Disturbance Events
- E.5. Satellite Time Reference (Cyber-Sciences STR-100)
- E.6. Communications Expansion Card (PXMCE card)
- E.7 . Communication Ports (PXMCE card)
- F Specifications
- specifications
- G Standard Cards
- G.1. Power Xpert Meter Cards
- G.2. Communication Main (PXMCM) Card
- G.4. 24V Source Outputs CM4 & CM6
- G.5. Power Supply Card PXMPS-1
- H Data Files
- H.3. Energy Logs
- H.4. Trend Logs
- I Root Certificate Authority Installation
- I.2. Installing Root CA with Mozilla Firefox
|
Page 196 IM02601004E www.eaton.B Standard & Extended Modbus Register MapsModbusRegisterHexModbusRegisterTypeId UnitsRegisterCount11312 2C2F PhaseC Float 211314 2C31 SystemMaximum Float 211316 2C33EvenHarmonic DistortionMagnitude(not supported in PXM 4000) NeutralCurrent Float Amps 211318 2C35 (not supported in PXM 4000) AUX PhaseAtoBVoltage Float Volts 211320 2C37 (not supported in PXM 4000) AUX PhaseBtoCVoltage Float Volts 211322 2C39 (not supported in PXM 4000) AUX PhaseCtoAVoltage Float Volts 211324 2C3B (not supported in PXM 4000) PhaseACurrent Float Amps 211326 2C3D (not supported in PXM 4000) PhaseAtoBVoltage Float Volts 211328 2C3F (not supported in PXM 4000) PhaseAtoNeutralVoltage Float Volts 211330 2C41 (not supported in PXM 4000) PhaseBCurrent Float Amps 211332 2C43 (not supported in PXM 4000) PhaseBtoCVoltage Float Volts 211334 2C45 (not supported in PXM 4000) PhaseBtoNeutralVoltage Float Volts 211336 2C47 (not supported in PXM 4000) PhaseCCurrent Float Amps 211338 2C49 (not supported in PXM 4000) PhaseCtoAVoltage Float Volts 211340 2C4B (not supported in PXM 4000) PhaseCtoNeutralVoltage Float Volts 211342 2C4DOddHarmonic DistortionMagnitude(not supported in PXM 4000) NeutralCurrent Float Amps 211344 2C4F (not supported in PXM 4000) AUX PhaseAtoBVoltage Float Volts 211346 2C51 (not supported in PXM 4000) AUX PhaseBtoCVoltage Float Volts 211348 2C53 (not supported in PXM 4000) AUX PhaseCtoAVoltage Float Volts 211350 2C55 (not supported in PXM 4000) PhaseACurrent Float Amps 211352 2C57 (not supported in PXM 4000) PhaseAtoBVoltage Float Volts 211354 2C59 (not supported in PXM 4000) PhaseAtoNeutralVoltage Float Volts 211356 2C5B (not supported in PXM 4000) PhaseBCurrent Float Amps 211358 2C5D (not supported in PXM 4000) PhaseBtoCVoltage Float Volts 211360 2C5F (not supported in PXM 4000) PhaseBtoNeutralVoltage Float Volts 211362 2C61 (not supported in PXM 4000) PhaseCCurrent Float Amps 211364 2C63 (not supported in PXM 4000) PhaseCtoAVoltage Float Volts 211366 2C65 (not supported in PXM 4000) PhaseCtoNeutralVoltage Float Volts 211368 2C67InterHarmonic DistortionMagnitude(not supported in PXM 4000) NeutralCurrent Float Amps 211370 2C69 (not supported in PXM 4000) AUX PhaseAtoBVoltage Float Volts 211372 2C6B (not supported in PXM 4000) AUX PhaseBtoCVoltage Float Volts 211374 2C6D (not supported in PXM 4000) AUX PhaseCtoAVoltage Float Volts 211376 2C6F (not supported in PXM 4000) PhaseACurrent Float Amps 211378 2C71 (not supported in PXM 4000) PhaseAtoBVoltage Float Volts 211380 2C73 (not supported in PXM 4000) PhaseAtoNeutralVoltage Float Volts 211382 2C75 (not supported in PXM 4000) PhaseBCurrent Float Amps 211384 2C77 (not supported in PXM 4000) PhaseBtoCVoltage Float Volts 211386 2C79 (not supported in PXM 4000) PhaseBtoNeutralVoltage Float Volts 2 PreviousNext |