Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Introduction
- Applicability
- Power Xpert Software Subscription
- AC Power Measurement Concepts Used in this Manual
- Feature Comparison between Power Xpert Meter Models
- Warranties
- Quick Start Guide for the Meter Module
- Power Supply Connections
- VT , VX & CT Connections
- Establishing Communications between the Meter Module and the Optional Graphic Display Module
- Operating the Display Module
- Programming the Meter Module using the Embedded Web Server Interface
- Programming the Meter Module via the Optional Communications Expansion Card
- Installation
- Mounting the Power Xpert Meter and Display Separately
- Wiring of CT & VT Connections
- CT & VT Connector Installation on the Power Xpert
- MeterDimensions
- WIRING
- Communication Wiring
- RS485 Network
- LEDs
- Display Link Addressing
- Introduction to Web Server Screens
- Home, Meter, Power, Quality, Energy, I/O, Events & Setup Screens
- The Meter Main Screen
- The Power Main Screen
- The Energy Main Screen
- Selecting Other Devices From The Events Screen
- I/O Screen
- Introduction to the Local Graphical Display
- The Main Screens
- Navigating from one Main Screen to another
- Accessing Details From All Main Screens
- The Events Main Screen
- The Setup Main Screen
- Functions on the Web Server
- Functions on the Graphical Display
- Meter
- Energy
- Quality
- Subcycle Disturbance
- Setup on the Web Server
- Setup on the Graphical Display
- Quick Setup
- Meter Setup and Commissioning
- Setup" This Display (Screen contrast, etc.)
- Network, Firmware & Product Information
- Password Setup
- Firmware Upgrade
- Upgrading From a PXM4000 to a PXM6000
- Troubleshooting & Maintenance
- Return Procedure
- Operating in Safe Mode
- Glossary
- A MODBUS Communication
- A.5. Register 2901 (Controls – Modbus RTU)
- A.8. Register 4609 (Product Status)
- A.10. Registers 4611-6332 (Real-Time Measured Values)
- B Standard & Extended Modbus Register Maps
- B.2. Extended Modbus Register Map
- B.3. Minimum and Maximum Register Map
- B.4. I/O Register Map
- B.5. Appendix E – Event Trigger Register Map
- B.6. Event Log Register Map
- B.7 . Trend and Profile Query Register Map
- B.8. Latest Min/Max/Avg Register Map
- B.9. Latest Demand Profile Register Map
- C SNMP Communication
- D Diagnostics
- D.1. Battery Status
- D.2. System Log
- D.3. Event Count
- D.4. Communications - Ethernet Status
- D.6. Communications - COM0, COM1, COM2, COM3 (Slave)
- D.7 . Communications - COM1, COM2, COM3 (Master)
- D.8. Communications - I/O Internal Input Status
- E Option Cards
- E.1. Power Xpert Meter Option Cards
- E.2. Optional I/O Card
- E.3. 1ms Time Stamping of Digital and Sub-Cycle Disturbance Events
- E.5. Satellite Time Reference (Cyber-Sciences STR-100)
- E.6. Communications Expansion Card (PXMCE card)
- E.7 . Communication Ports (PXMCE card)
- F Specifications
- specifications
- G Standard Cards
- G.1. Power Xpert Meter Cards
- G.2. Communication Main (PXMCM) Card
- G.4. 24V Source Outputs CM4 & CM6
- G.5. Power Supply Card PXMPS-1
- H Data Files
- H.3. Energy Logs
- H.4. Trend Logs
- I Root Certificate Authority Installation
- I.2. Installing Root CA with Mozilla Firefox
|
www.eaton.com IM02601004E Page 231B Standard & Extended Modbus Register MapsMin Reg (dec)Min Reg (hex)Max Reg (dec)Max Reg (hex)Average Reg (dec)Average Reg (hex)DescriptionIntervalTypeUnits34020 84e3 34022 84e5 34024 84e7 InterHarmVcaPct 15 min float ratio34026 84e9 34028 84eb 34030 84ed TotalHarmVcaPct 15 min float ratio34032 84ef 34034 84f1 34036 84f3 EvenHarmVabxmrPct 15 min float ratio34038 84f5 34040 84f7 34042 84f9 OddHarmVabxmrPct 15 min float ratio34044 84fb 34046 84fd 34048 84ff InterHarmVabxmrPct 15 min float ratio34050 8501 34052 8503 34054 8505 TotalHarmVabxmrPct 15 min float ratio34056 8507 34058 8509 34060 850b EvenHarmVbcxmrPct 15 min float ratio34062 850d 34064 850f 34066 8511 OddHarmVbcxmrPct 15 min float ratio34068 8513 34070 8515 34072 8517 InterHarmVbcxmrPct 15 min float ratio34074 8519 34076 851b 34078 851d TotalHarmVbcxmrPct 15 min float ratio34080 851f 34082 8521 34084 8523 EvenHarmVcaxmrPct 15 min float ratio34086 8525 34088 8527 34090 8529 OddHarmVcaxmrPct 15 min float ratio34092 852b 34094 852d 34096 852f InterHarmVcaxmrPct 15 min float ratio34098 8531 34100 8533 34102 8535 TotalHarmVcaxmrPct 15 min float ratio34104 8537 34106 8539 34108 853b EvenHarmIaPct 15 min float ratio34110 853d 34112 853f 34114 8541 OddHarmIaPct 15 min float ratio34116 8543 34118 8545 34120 8547 InterHarmIaPct 15 min float ratio34122 8549 34124 854b 34126 854d TotalHarmIaPct 15 min float ratio34128 854f 34130 8551 34132 8553 EvenHarmIbPct 15 min float ratio34134 8555 34136 8557 34138 8559 OddHarmIbPct 15 min float ratio34140 855b 34142 855d 34144 855f InterHarmIbPct 15 min float ratio34146 8561 34148 8563 34150 8565 TotalHarmIbPct 15 min float ratio34152 8567 34154 8569 34156 856b EvenHarmIcPct 15 min float ratio34158 856d 34160 856f 34162 8571 OddHarmIcPct 15 min float ratio34164 8573 34166 8575 34168 8577 InterHarmIcPct 15 min float ratio34170 8579 34172 857b 34174 857d TotalHarmIcPct 15 min float ratio34176 857f 34178 8581 34180 8583 EvenHarmInPct 15 min float ratio34182 8585 34184 8587 34186 8589 OddHarmInPct 15 min float ratio34188 858b 34190 858d 34192 858f InterHarmInPct 15 min float ratio34194 8591 34196 8593 34198 8595 TotalHarmInPct 15 min float ratioB.9. Latest Demand Profile Register MapThe following registers are organized in groups. Each row represents the latest energy demand profile value. The interval ofthe data is dictated by the configurable demand profile interval available in the meter configuration. PreviousNext |