5-198 F60 FEEDER PROTECTION SYSTEM – INSTRUCTION MANUALFLEXLOGIC CHAPTER 5: SETTINGS5TRIP BUS 2 to 6 Same set of operands as shown for TRIP BUS 1ELEMENT:UnderfrequencyUNDERFREQ 1 PKPUNDERFREQ 1 OPUNDERFREQ 1 DPOUnderfrequency 1 has picked upUnderfrequency 1 has operatedUnderfrequency 1 has dropped outUNDERFREQ 2 to 6 Same set of operands as shown for UNDERFREQ 1ELEMENT:Wattmetric zero-sequence directionalWATTMETRIC 1 PKPWATTMETRIC 1 OPWattmetric directional element 1 has picked upWattmetric directional element 1 has operatedWATTMETRIC 2 Same set of operands as per WATTMETRIC 1FIXED OPERANDS Off Logic = 0. Does nothing and can be used as a delimiter in an equation list;used as ‘Disable’ by other features.On Logic = 1. Can be used as a test setting.INPUTS/OUTPUTS:Contact inputsCont Ip 1 OnCont Ip 2 On↓Cont Ip 1 OffCont Ip 2 Off↓Cont Ip 120 OnCont Ip 120 Off(does not appear unless ordered)(does not appear unless ordered)↓(does not appear unless ordered)(does not appear unless ordered)↓(does not appear unless ordered)(does not appear unless ordered)INPUTS/OUTPUTS:Contact outputs,current(from detector onform-A output only)Cont Op 1 IOnCont Op 2 IOn↓Cont Op 72 IOn(does not appear unless ordered)(does not appear unless ordered)↓(does not appear unless ordered)INPUTS/OUTPUTS:Contact outputs,voltage(from detector onform-A output only)Cont Op 1 VOnCont Op 2 VOn↓Cont Op 72 VOn(does not appear unless ordered)(does not appear unless ordered)↓(does not appear unless ordered)Cont Op 1 VOffCont Op 2 VOff↓Cont Op 72 VOff(does not appear unless ordered)(does not appear unless ordered)↓(does not appear unless ordered)INPUTS/OUTPUTS:Direct inputsDIRECT INPUT 1 On↓DIRECT INPUT 32 OnFlag is set, logic=1↓Flag is set, logic=1INPUTS/OUTPUTS:RxGOOSE DPSRxG DPS 1 BADRxG DPS 1 INTERMRxG DPS 1 OFFRxG DPS 1 ONAsserted while the RxGOOSE double-point status input is in the bad stateAsserted while the RxGOOSE double-point status input is in the intermediatestateAsserted while the RxGOOSE double-point status input is offAsserted while the RxGOOSE double-point status input is onRxG DPS 2 to 5 Same set of operands as per RxG DPS 1INPUTS/OUTPUTS:RxGOOSE BooleansRxG Bool 1 OnRxG Bool 2 OnRxG Bool 3 On↓RxG Bool 256 OnFlag is set, logic=1Flag is set, logic=1Flag is set, logic=1↓Flag is set, logic=1INPUTS/OUTPUTS:Virtual inputsVirt Ip 1 OnVirt Ip 2 OnVirt Ip 3 On↓Virt Ip 64 OnFlag is set, logic=1Flag is set, logic=1Flag is set, logic=1↓Flag is set, logic=1INPUTS/OUTPUTS:Virtual outputsVirt Op 1 OnVirt Op 2 OnVirt Op 3 On↓Virt Op 96 OnFlag is set, logic=1Flag is set, logic=1Flag is set, logic=1↓Flag is set, logic=1Operand type Operand syntax Operand description