D-4 F60 FEEDER PROTECTION SYSTEM – INSTRUCTION MANUALREVISION HISTORY APPENDIX D: MISCELLANEOUSDTable D-4: Major changes for F60 manual version AE1 (English)Table D-5: Major changes for F60 manual version AC1 (English)Page Description--- General revision--- Added routable GOOSE content in chapters 2 and 53-39 Updated RS422 and Fiber Interface Connection figure for the clock channels (from 7a and 7b to 1a and 1b)4- Added Engineer content5- Updated IEC 61850 contentA- Updated FlexAnalog table for most UR productsPage Description--- General revision. Added online help and updated generic online help.--- Deleted EAC logo from title page and deleted EAC certification from Approvals specifications because document nottranslated into Russian--- Updated Breaker Arcing Current content, including FlexLogic operands table, settings, logic diagram, actual values, Modbusmemory map--- Updated Synchrocheck content including settings, logic diagram, and number of elements from four to six in interfacechapter, FlexLogic operands table, settings, actual values, FlexAnalog table, features per product table, Modbus memory map,IMD tables--- Updated Fault Report and Fault Location content, including settings, actual values, and theory of operation chapters, andModbus memory map. Increased number of elements to three.--- Added CT Failure Detector content to description, FlexLogic operands table, settings, features per product table, Modbusmemory map, IMD table--- Updated number of Breaker Restrike elements, increasing from one to four, in FlexLogic operands table, settings, features perproduct table, Modbus memory map--- Added Pilot POTT and Pilot POTT (1P) content as per D60 and L90 to product description, specifications, FlexLogic operandstable, settings, features per product table, Modbus memory map, IMD tables. Did not add Single-Pole Tripping section toTheory of Operation chapter because single-pole tripping does not apply to F60. Did not add new Application of Settingschapter to add Protection Signaling Schemes section because section is POTT and not Pilot POTT.--- Updated Autoreclose 3P number from 2 to 4 in FlexLogic operands table, settings, actual values, features per product table,Modbus memory map--- Updated Breaker Failure number from 2 to 4 in FlexLogic operands table, settings, features per product table, Modbusmemory map--- Updated Ground Instantaneous Overcurrent number from 8 to 6 in FlexLogic operands table, settings, features per producttable, Modbus memory map--- Update Neutral Instantaneous Overcurrent number from 8 to 6 in FlexLogic operands table, settings, features per producttable, Modbus memory map--- Updated number of Phase Instantaneous Overcurrent elements in FlexLogic operands table, settings, features per producttable, Modbus memory map--- Updated number of Restricted Ground Fault elements in FlexLogic operands table, settings, actual values, features perproduct table, Modbus memory map--- Added Permissive Over-reaching Transfer Trip (POTT3) and Directional Comparison Blocking 3 (DCB3) pilot schemes toFlexLogic operand table, settings, features per product table2-2 Updated Figure 2-1 single-line diagram2- Updated several specifications, such as TOC, IOC, number of FlexLogic lines4-30 Added FlexLogic Design and Monitoring using Engineer section to end of Interfaces chapter5-38 Added PRT FUNCTION settings in Network section to enable/disable each Ethernet port5-49 Updated IEC 61850 section5-61 Added Support for Routable GOOSE section5-193 Updated number of FlexLogic lines from 512 to 1024 in FlexLogic Equation Editor settings section10-1 Added Monitoring section10-2 Added Retrieve Files sectionC- Added Command Line Interface appendix