APPENDIX D: MISCELLANEOUS REVISION HISTORYF60 FEEDER PROTECTION SYSTEM – INSTRUCTION MANUAL D-3DTable D-2: Major changes for F60 manual version AF1 (English)Table D-3: Major changes for F60 manual version AE3 (English)1601-0093-AF1 7.6x 30 June 2017 17-3779Page Description--- General revision--- Updated "faceplate" to "front panel" for consistency and to reflect web site--- Added graphical front panel option to order codes and specifications in chapter 2, Interfaces chapter 4, Settings chapter 5,Actual Values chapter 6--- Added PEAP-GTC and PAP protocols for authenticating user logins when using a RADIUS server. Added to Settings > ProductSetup > Security > RADIUS Authentication Method and to Modbus memory map and F codes.--- Updated Contact Inputs from 96 to 120 and Contact Outputs from 64 to 72 in Product Description in chapter 2 and FlexLogicoperands table in chapter 5--- Updated Ground Instantaneous Overcurrent element number from 6 to 8 in FlexLogic operands table, settings, features perproduct table, Modbus memory map--- Updated Neutral Instantaneous Overcurrent element number from 6 to 12 in FlexLogic operands table, settings, features perproduct table, Modbus memory map--- Updated Neutral Time Overcurrent element number from 4 to 6 in FlexLogic operands table, settings, features per producttable, Modbus memory map--- Updated Phase Instantaneous Overcurrent element number from 8 to 12 in FlexLogic operands table, settings, features perproduct table, Modbus memory map--- Updated Phase Time Overcurrent element from 4 to 6 in FlexLogic operands table, settings, features per product table,Modbus memory map--- Updated Breaker Restrike number from 4 to 3 in specifications, FlexLogic operands table, settings, features per product table,Modbus memory map--- Updated Current CT Settings number from 4 to 6 in FlexLogic operands table, settings, features per product table, andModbus memory map--- Updated Ground Instantaneous number from 6 to 12 in FlexLogic operands table, settings, features per product table,Modbus memory map--- Updated Ground Time Overcurrent number from 4 to 6 in FlexLogic operands table, settings, features per product table,Modbus memory map3-39 Updated RS422 and Fiber Interface Connection figure for the clock channels (from 7a and 7b to 1a and 1b)3-70 Added Connect to a D400 Gateway section4-43 Updated LED Labelling instructions for the new Front Panel Label Designer4-50 Added Standard Front Panel section for labelling LEDs and pushbuttons5-106 Added USB Port section to enable/disable the USB port on the graphical front panel5-124 Updated User-programmable Pushbuttons section as per specifications5-147 Updated Breakers section as per specifications5-152 Updated Disconnect Switches section as per specifications10-5 Added Convert Device Settings section10-7 Added Copy Settings to Other Device section10-15 Added Replace Front Panel section for retrofit with the new graphical front panelPage Description--- General revision2- Updated order codes5-152 Updated PMU Basic Configuration settings10-5 Added Copy Settings to Other Device sectionManual P/N F60 revision Release date ECO