Chapter 7. Configuring the TransmitterTransPort ® PT900 User’s Manual 1197.3.2a Programming the TOTALIZER OptionThe TOTALIZER option enables the user to reset the values of all batch and inventorytotalizers (i.e., Forward Totalizer, Reverse Totalizer, Net Totalizer and TotalizerTime) in all channels to zero by clicking the RESET button.The RESPONSE option enables the user to choose the time interval in secondsbetween any two measurements:• If Custom is selected from the drop-down list, the following options areavailable: 1s, 2s, 5s, 10s, 30s, 60s, 100s, 200s, 300s or 500s.• If Fast is selected from the drop-down list, the default time interval isused.7.3.2b Programming the POWER SAVING MODE OptionThe POWER SAVING MODE slide switch changes the PT900 transmitter into apower saving measurement mode. After turning the POWER SAVING MODE to On,the following parameters must be set:• From the MEASUREMENT TIME drop down list, select one of the followingoptions: 5min, 10min, 30min or 60min.• From the SLEEP TIME drop down list, select one of the following options:30min, 60min, 60min, 120min, 150min, 180min, 210min or 240min.For example if the MEASUREMENT TIME is 5 min and the SLEEP TIME is 30 min, thePT900 transmitter would take measurements for 5 minutes and then sleep for30 minutes, before repeating the cycle.