Appendix A. SpecificationsTransPort ® PT900 User’s Manual 151Appendix A. SpecificationsA.1 Operation and PerformanceFluid TypesLiquids: Acoustically conductive fluids, including most clean liquids, and manyliquids with limited amounts of entrained solids or gas bubblesFlow MeasurementPatented Correlation Transit-Time™ modePipe SizesStandard: 0.5 to 24 in. (15 to 600 mm)Optional: up to 300 in. (7500 mm) available upon requestPipe Wall Thicknessup to 3 in. (76.2 mm)Pipe MaterialAll metals and most plasticsConsult GE for concrete, composite materials and highly corroded or lined pipes.Accuracy±1% of reading (2in./50mm or greater pipe sizes)±2% of reading (0.5in./15mm to <2in./50mm pipe sizes)Installation assumes a fully developed symmetrical flow profile (typically 10 pipediameters upstream and 5 pipe diameters downstream of straight pipe run). Finalinstallation accuracy is a function of multiple factors including fluid, temperaturerange, pipe centricity among other factors.Repeatability±0.2% of readingRange (Bidirectional)0.1 to 40 ft/s (0.03 to 12.19 m/s)Response TimeUp to 2 HzMeasurement ParametersVelocity, Volume, Mass, Energy, Total FlowChannels1 or 2 channels