195specified, this command displays the DC output state of all PoE power supplies connected to the IRFfabric. (In IRF mode.)|: Filters command output by specifying a regular expression. For more information about regularexpressions, see Fundamentals Configuration Guide.begin: Displays the first line that matches the specified regular expression and all lines that follow.exclude: Displays all lines that do not match the specified regular expression.include: Displays all lines that match the specified regular expression.regular-expression: Specifies a regular expression, a case-sensitive string of 1 to 256 characters.Examples# In standalone mode, display the DC output state of the external PoE power supply. display poe-power dc-output stateDC Output State : Normal# In IRF mode, display the DC output state of external PoE power supplies. display poe-power dc-output stateChassis 1:DC Output State : NormalChassis 2:DC Output State : Normaldisplay poe-power dc-output valueUse display poe-power dc-output value to display DC output values of external PoE power supplies.SyntaxIn standalone mode:display poe-power dc-output value [ | { begin | exclude | include } regular-expression ]In IRF mode:display poe-power dc-output value [ chassis chassis-number ] [ | { begin | exclude | include }regular-expression ]ViewsAny viewDefault command level1: Monitor levelParameterschassis chassis-number: Displays the DC output values of the external PoE power supply for an IRFmember device. The chassis-number argument represents the IRF member ID of the device. If no IRFmember ID is specified, this command displays the DC output values of all PoE power supplies connectedto the IRF fabric. (In IRF mode.)|: Filters command output by specifying a regular expression. For more information about regularexpressions, see Fundamentals Configuration Guide.begin: Displays the first line that matches the specified regular expression and all lines that follow.exclude: Displays all lines that do not match the specified regular expression.