Note: See “System replaceable units” on page 144 to determine which components should be replaced by a fieldservice technician.Error code/symptom FRU/action166-070-000 System Management: Failed(Unable to communicate with RSA. It maybe busy. Run the test again.)1. Flash latest levels of firmware (BIOS, service processor,diagnostics)2. Rerun diagnostic test.3. Correct other error conditions (including failed system managementtests and items logged in Remote Supervisor Adapter II SlimLinesystem-error log and BMC log) and retry.4. Disconnect all server and option power cords from server, wait 30seconds, reconnect, and retry.5. Remote Supervisor Adapter II SlimLine.166-198-000 System Management:Aborted(Unable to communicate with RSA. It maybe busy. Run the test again.)1. Run the diagnostic test again.2. Correct other error conditions and retry. These include other failedsystem management tests and items logged in the system-error logof the optional Remote Supervisor Adapter II SlimLine.3. Disconnect all server and option power cords from the server, wait30 seconds, reconnect, and retry.4. Remote Supervisor Adapter II SlimLine, if installed.5. System board.166-260-000 System Management: Failed(Restart RSA error. After restarting, RSAcommunication was lost. Unplug and coldboot to reset RSA.)1. Disconnect all server and option power cords from the server,wait 30 seconds, reconnect, and retry.2. Reseat the Remote Supervisor Adapter II SlimLine.3. Remote Supervisor Adapter II SlimLine.166-342-000 System Management: Failed(RSA adapter BIST indicate failed tests.) 1. Ensure the latest firmware levels for Remote SupervisorAdapter II SlimLine and BIOS are installed.2. Disconnect all server and option power cords from server, wait 30seconds, reconnect, and retry.3. Remote Supervisor Adapter II SlimLine.166-400-000 System Management: Failed(BMC self test result failed tests: x where x= Flash, RAM, or ROM.)1. Reflash or update firmware for BMC.2. System board.166-404-001 System Management: Failed(BMC indicates failure in I2C bus test.) 1. Disconnect all server and option power cords from the server,wait 30 seconds, reconnect, and retry.2. Reflash or update firmware for BMC.3. Power backplane4. System board.166-406-001 System Management: Failed(BMC indicates failure in I2C bus test.) 1. Disconnect all server and option power cords from the server,wait 30 seconds, reconnect, and retry.2. Reflash or update firmware for BMC.3. SCSI cable.4. SCSI backplane.5. System board.Chapter 6. Symptom-to-FRU index 119