Note: See “System replaceable units” on page 144 to determine which components should be replaced by a fieldservice technician.Error code/symptom FRU/action202-XXX-001(Failed system cache test) 1. Microprocessor 12. System board202-XXX-002(Failed system cache test) 1. Microprocessor 22. System board206-XXX-000(Failed diskette drive test) 1. Rerun the test with a different diskette.2. Make sure that the distance between monitors and diskette drives isat least 76 mm (3 in.).3. Diskette drive cables.4. Diskette drive.5. System board.215-XXX-000(Failed IDE CD-ROM drive test) 1. Rerun the test with a different CD-ROM.2. CD-ROM drive cables.3. CD-ROM drive.4. System board.217-198-XXX(Could not establish drive parameters) 1. Check cable and termination.2. Hard disk drive backplane.3. Hard disk drive.217-XXX-000(Failed hard disk drive test)Note: If RAID is configured, the hard diskdrive number refers to the RAID logicalarray.v Hard disk drive 1217-XXX-001(Failed hard disk test)Note: If RAID is configured, the hard disknumber refers to the RAID logical array.v Hard disk drive 2217-XXX-002(Failed hard disk test)Note: If RAID is configured, the hard disknumber refers to the RAID logical array.v Hard disk drive 3217-XXX-003(Failed hard disk test)Note: If RAID is configured, the hard disknumber refers to the RAID logical array.v Hard disk drive 4217-XXX-004(Failed hard disk test)Note: If RAID is configured, the hard disknumber refers to the RAID logical array.v Hard disk drive 5217-XXX-005(Failed hard disk test)Note: If RAID is configured, the hard disknumber refers to the RAID logical array.v Hard disk drive 6Chapter 6. Symptom-to-FRU index 121