Replacing hot-swap fansThe server comes with four hot-swap fans: two front fans (fans 1 and 2), and twocenter fans (fans 3 and 4). You do not have to turn off the power to the server toreplace a hot-swap fan.If the server is equipped with the IBM xSeries 670-Watt Hot-swap Power-Supplyoption, two rear fans (fans 5 and 6) must also be installed on the server. Forinformation on replacing these fans or installing this option, see “Replacing a rearfan (5 or 6)” on page 20 or “Installing the 670-Watt hot-swap power-supply option”on page 21.Attention: To help ensure proper cooling, if a fan fails, replace it within 48 hours.The following illustration shows how to replace hot-swap fans.Center fan3 or 4ReleaseleverHot-swap fanHot-swap fanassemblyFront fan1 or 2Determine which fan to replace by checking the LEDs on the fans. The front fans,center fans, and rear fans are installed differently from each other. This sectioncontains separate instructions for each group of fans.Chapter 3. Installing options 17