10. None of the resources that are associated with the B600 5311 SRCs are disk units that were addedto the partition since the last IPL of the partition.Has a scratch install recently been performed on the partition that is reporting the error(s)?v No: Continue with the next step.v Yes: Go to step 13 (See page 146).11. If a scratch install was not performed, was the clear configuration data option recently used todiscontinue LPAR use?v Yes: Continue with the next step.v No: The Clear configuration data option was not used. Contact your next level of support.This ends the procedure.12. Perform the following to clear non-configured disk unit configuration data:a. Go to SST/DST in the partition and select Work with system partitions—>Recoverconfiguration data—>Clear non-configured disk unit configuration data.b. Select each unit in the list which is new to the system and press Enter.c. Continue the system IPL.This ends the procedure.13. Was the load source device previously mirrored before the scratch install?v Yes: Continue with the next step.v No: Go to step 15 (See page 146).14. Perform the following to clear the old configuration data from the disk unit that was mirroring the oldload source diska. Go to SST/DST in the partition and select Work with system partitions—>Recoverconfiguration data—>Clear non-configured disk unit configuration data.b. Select the former load source mirror in the list and press Enter.15. Is the Primary partition reporting the B600 5311 error(s)?v No: This ends the procedure.v Yes: Does the customer want multiple partitions on the system?– No: This ends the procedure.– Yes: Use the Recover primary partition configuration data option to retrieve the LPARconfiguration data from other devices in the system.a. Go to SST/DST in the primary partition and select Work with systempartitions—>Recover configuration data—>Recover primary partition configurationdata. The system will perform an automatic IPL.b. Verify the information that appears.- The device should be a former load source device from a secondary partition.- The time and date should reflect a time when that partition was active. It should be morerecent than the last change to the logical partition configuration.This ends the procedure.Operations Console PIPsFor use by authorized service providers.For direct cable only.This topic contains the procedures necessary to isolate a failure with the iSeries Operations Console.The following symptoms can be caused by iSeries Operations Console failing to connect:v One of the following SRCs:– A6xx 5001 or B6xx 5001146 iSeries: iSeries Server 270, 800, 810, 820, 825, 830, 840, 870, 890, SB2, and SB3 Hardware Problem Analysis andIsolation