– 6.0 meters - part 21F9469– 15.0 meters - part 21F9358– 30.0 meters - part 21F9359– 60.0 meters - part 21F9360– 100.0 meters (SPCN optical cable) - part 21F9415– SPCN optical adapter - part 90H6287– SPCN port cable (frame-to-node) - part 21F9362– Frame-to-frame cable - part 87G6235– Integrated xSeries (TM) Server SPCN-Y cable assembly - part 04N265212. Is the SRC 1xxx-2613?v No: Continue with the next step.v Yes: Go to Determine line cord, plug, and receptacle type in the Plan for hardware and softwaretopic in Information Center, to determine the power cable part number for systems in your countryor region. This information is also available in the Plan for hardware and software book underthe Power topic.13. Is the SRC 1xxx-8940, 8941, 8942 or 8943?v Yes: Continue with the next step.v No: Go to “Starting point for all problems” on page 2.This ends the procedure.14. Reseat the RS485 cable. Does this correct the problem?Note: It may take up to one minute for the frame ID to stop blinking.v Yes: This ends the procedure.v No: Continue with the next step.15. Exchange the RS485 cable assembly part - 21P4162. Does this correct the problem?Note: It may take up to one minute for the frame ID to stop blinking.v Yes: This ends the procedure.v No: Go to the next FRU in the list.This ends the procedure.CBLPWRFor use by authorized service providers.A power or AC line cord may be the failing item.Use the diagram below to view the power cable locations, in conjunction with the tables below that givemore details. The tables include:v Power cables (See page 302)v AC line cords (See page 303)Figure 1. Part locations for power cablesAnalyze hardware problems 301