5ANTRIEBSTECHNIK5 1 5KEB COMBIVERT F4-CName: Basis5Section PageDate© KEB Antriebstechnik, 1997All Rights reservedChapter20.03.98Parameter5.1.2 Parameter ListingF4-CPr - Parameter Addr. min max default [?] see page(s)Pr 4 Pole Number 012A - - √ 2 12 2 4 - 11.2.4Pr 5 Malfunction Code 0105 - - - 0 65535 1 - - 11.2.4Pr 6 Control Word 0106 - - √ 0 65535 1 0 - 11.2.4; 11.2.8Pr 7 Status Word 0107 - - - 0 65535 1 - - 11.2.5; 11.2.8Pr 8 Nominal Speed Value 0108 - - √ -32767 32767 1 0 rpm 11.2.5; 6.4.5Pr 9 Actual Speed Value 0109 - - - -32767 32767 1 - rpm 11.2.5Pr 10 Speed Min. Amount 010A - - √ 0 32767 1 0 rpm 11.2.5Pr 11 Speed Max. Amount 010B - - √ 0 32767 1 1500 rpm 11.2.5Pr 16 Acceleration Delta Speed 0110 - - √ 1 32767 1 1500 rpm 11.2.5Pr 18 Acceleration Delta Time 0112 - - √ 0 32767 1 10 sec 11.2.6Pr 25 Deceleration Delta Speed 0119 - - √ 1 32767 1 1500 rpm 11.2.6Pr 27 Deceleration Delta Time 011B - - √ 0 32767 1 10 sec 11.2.6Pr 37 Speed Control Variable 0125 - - - -32767 32767 1 - rpm 11.2.6; 6.4.5Pr 38 Set Value Percentage 0126 - - √ -200 200 0,61 0 % 11.2.6Pr 39 Percentage Reference Value 0127 - - √ 0 32767 1 1500 rpm 11.2.7Pr 40 Actual Percentage 0128 - - - -200 200 0,61 - % 11.2.7Pr 41 Percentage Control Variable 0129 - - - -200 200 0,61 - % 11.2.7ru - Parameter Addr. min max default [?] see page(s)ru 0 Inverter State 2000 - - - table - - 6.1.5; 6.7.6; 6.12.4ru 1 Actual Speed Display 2001 - - - 0,5 - rpm 6.1.7; 6.10.9; 6.10.10ru 3 Actual Frequency Display 2003 - - - -409,5875 409,5875 0,0125 - Hz 6.1.7; 6.7.6ru 4 Set Speed Display 2004 - - - 0,5 - rpm 6.1.7; 6.4.12ru 6 Set Frequency Display 2006 - - - -409,5875 409,5875 0,0125 - Hz 6.1.8; 6.4.12ru 7 Actual Inverter Utilization 2007 - - - 0 200 1 - % 6.1.8; 6.7.6ru 8 Peak Inverter Utilization 2008 - - √ 0 200 1 - % 6.1.8ru 9 Apparent Current 2009 - - - 0,1 - A 6.1.8ru 10 Active Current 200A - - - 0,1 - A 6.1.8ru 11 Actual DC Voltage 200B - - - 1 - V 6.1.9ru 12 Peak DC Voltage 200C - - √ 1 - V 6.1.9ru 13 Output Voltage 200D - - - 0 1 - Vru 14 Input Terminal State 200E - - - table - - 6.1.9; 6.3.3; 6.3.4ru 15 Output Terminal State 200F - - - table - - 6.1.10; 6.3.13ru 16 Internal Input State 2010 - - - table - - 6.1.10; 6.3.3; 6.3.8ru 17 Internal Output State 2011 - - - table - - 6.1.11ru 18 Actual Parameterset 2012 - - - table - - 6.1.11ru 22 Ref 1 display 2016 - - - -100,0 100,0 0,1 - % 6.1.11; 6.2.10ru 23 Ref 2 display 2017 - - - -100,0 100,0 0,1 - % 6.1.11; 6.2.10; 6.4.5ru 24 OL Counter Display 2018 - - - 0 100 1 - % 6.1.12; 6.4.5ru 29 Heat Sink Temperature 201D - - - 1 - °C 6.1.12ru 30 Ext. PI Output Display 201E - - - -100,0 100,0 0,1 - % 6.1.12; 6.4.5; 6.11.5ru 31 Power On Counter 201F - - √ 0 65535 1 - h 6.1.12ru 32 Modulation On Counter 2020 - - √ 0 65535 1 - h 6.1.12ru 33 Timer A Act. Value 2021 - - √ 0 327,67 0,01 0,00 s / h 6.1.13; 6.9.18ru 34 Motorpoti Act. Value 2022 √ - √ -100,00 100,00 0,01 0,00 % 6.1.13; 6.9.14; 6.9.15ru 41 Analog Out 1 Display 2029 - - - -100,0 100,0 0,1 - % 6.1.13ru 43 Programmable Display 202B - - - -32767 32767 - - - 6.1.13; 6.9.23ru 44 Act. Switching Freq. 202C - - - 1 16 1 - kHz 6.1.13; 6.5.6ru 45 Aanalog Option Display 202D - - - 0,1 - % 6.2.10; 6.10.9ru 46 Ramp Frequency 202E - - - 0,0125 - Hz 6.4.12ru 47 Act Encoder Frequency 202F - - - 0,0125 - Hz 6.10.10oP - Parameter Addr. min max default [?] see page(s)oP 0 Reference Source 2100 √ √ √ 0 26 1 1 - 6.4.5; 6.4.6; 6.4.8; 6.9.15oP 1 Freq. Reference Setting Abs. 2101 √ - √ -409,5875 409,5875 0,0125 0,0000 Hz 6.4.5oP 2 Freq. Reference Setting % 2102 √ - √ -100,0 100,0 0,1 0,0 % 6.4.5oP 3 Rotation Setting 2103 √ √ √ 0 2 1 0 - 6.4.6oP 4 Min. Freq. Reference Forward 2104 √ - √ 0,0000 409,5875 0,0125 0,0000 Hz 4.4.5; 6.4.5; 6.4.9; 6.9.14oP 5 Max. Freq. Reference Forward 2105 √ - √ 0,0000 409,5875 0,0125 70,0000 Hz 6.4.5; 6.4.9oP 6 Min. Freq. Reference Reverse 2106 √ - √ -0,0125 : off 409,5875 0,0125 -0,0125 : off Hz 6.4.5; 6.4.9; 6.9.14oP 7 Max. Freq. Reference Reverse 2107 √ - √ -0,0125 : off 409,5875 0,0125 -0,0125 : off Hz 6.4.5; 6.4.9oP 8 Abs. Max. Freq. Forward 2108 √ - √ 0,0000 409,5875 0,0125 409,5875 Hz 6.4.9oP 9 Abs. Max. Freq. Reverse 2109 √ - √ -0,0125 : off 409,5875 0,0125 -0,0125 : off Hz 6.4.9oP 10 Acc Dec Mode 210A √ √ √ 0 255 1 0 - 6.4.12; 6.4.16oP 11 Acceleration Time Forward 210B √ - √ 0,00 300,00 0,01 10,00 sec 6.4.13; 6.4.14oP 12 Deceleration Time Forward 210C √ - √ 0,00 300,00 0,01 10,00 sec 6.4.13; 6.4.14oP 13 Acceleration Time Reverse 210D √ - √ -0,01 : off 300,00 0,01 -0,01 : off sec 6.4.13; 6.4.14oP 14 Deceleration Time Reverse 210E √ - √ -0,01 : off 300,00 0,01 -0,01 : off sec 6.4.13; 6.4.14oP 15 S-Curve Time Acc. Forward 210F √ - √ 0 : off 5,00 0,01 0 : off sec 6.4.14oP 16 S-Curve Time Dec. Forward 2110 √ - √ 0 : off 5,00 0,01 0 : off sec 6.4.14oP 17 S-Curve Time Acc. Reverse 2111 √ - √ 0 : off 5,00 0,01 0 : off sec 6.4.14oP 18 S-Curve Time Dec. Reverse 2112 √ - √ 0 : off 5,00 0,01 0 : off sec 6.4.14oP 22 Step Frequency 1 2116 √ - √ -409,5875 409,5875 0,0125 5,0000 Hz 6.4.11oP 23 Step Frequency 2 2117 √ - √ -409,5875 409,5875 0,0125 50,0000 Hz 6.4.11oP 24 Step Frequency 3 2118 √ - √ -409,5875 409,5875 0,0125 70,0000 Hz 6.4.11oP 25 Step Frequency Mode 2119 √ √ √ 0 3 1 2 - 6.4.11oP 26 Motorpoti Function 211A - - √ 0 15 1 8 - 6.1.13; 6.9.14oP 27 Motorpoti Min. Value 211B - - √ -100,00 100,00 0,01 0,00 % 6.9.14oP 28 Motorpoti Max. Value 211C - - √ -100,00 100,00 0,01 100,00 % 6.9.14; 6.9.15