3ANTRIEBSTECHNIK6 1 309.04.99KEB COMBIVERT F4-CName: Basis6© KEB Antriebstechnik, 1999All Rights reservedFunctional DescriptionChapter Section PageDateOperating and Appliance Displays6.1.1 Summary ofru-Parameters6.1 Operating andAppliance Displays6.1.2 Summary ofIn-Parametersru. 0 Inverter statusru. 1 Actual speed displayru. 3 Actual frequency displayru. 4 Setpoint speed displayru. 6 Setpoint frequency displayru. 7 Actual loadru. 8 Peak loadru. 9 Apparent currentru. 10 Active currentru. 11 DC-link voltageru. 12 DC-link voltage /peak valueru. 13 Output voltageru. 14 Input terminal statusru. 15 Output terminal statusru. 16 Internal input statusru. 17 Internal output statusIn. 0 Inverter typeIn. 1 Rated inverter currentIn. 2 Maximum output frequencyIn. 3 Maximum switching frequencyIn. 4 Software - IdentificationIn. 5 Software dateIn. 6 Config-File-No.In. 7 Serial number (date)In. 8 Serial number (counter)In. 9 Serial number (Ackn.-No. High)In. 10 Serial number (Ackn.-No. Low)In. 11 Customer number (High)In. 12 Customer number (Low)In. 13 QS-NumberIn. 15 REF Offset+In. 16 REF Offset-In. 17 REF Offset Gain+In. 18 REF Offset Gain-In. 19 REF2 0-10V OffsetIn. 20 REF2 0-10V GainIn. 21 REF2 0-20mA OffsetIn. 22 REF2 0-20mA GainIn. 23 REF2 4-20mA OffsetIn. 24 REF2 4-20mA GainIn. 40 Last errorIn. 41 Error counter OCIn. 42 Error counter OLIn. 43 Error counter OPIn. 44 Error counter OHIn. 45 Error counter WDIn. 58 User Parameter 1In. 59 User Parameter 2The parameter groups „ru“ and „In“ are described in this chapter. They serve forthe operational monitoring, error analysis and evaluation as well as for the unitidentification.The ru- (run) parameter group represents the multimeter of the inverter. Herespeeds, currents, voltages etc. are displayed which allow a conclusion on theoperating condition of the drive. This can be especially helpful for the start-up of aplant or with regard to trouble shooting. Following parameters are available:The In- (Information) parameter group includes data and information about theidentification of the hardware and software as well as to the type and number ofthe errors that occurred. Following parameters are available:ru. 18 Active parameter setru. 22 Ref +/- displayru. 23 Ref displayru. 24 Display OL - counterru. 29 Heat sink temperatureru. 30 Display PI-controller outputru. 31 Operating hours-meter 1 (inverter connected tosupply)ru. 32 Operating hours meter 2 (inverter modulates)ru. 33 Display counter Aru. 34 Motorpoti - current valueru. 41 Analog output 1 displayru. 43 Programmable displayru. 44 Operating frequency displayru. 45 Display analog optionru. 46 Ramp output frequencyru. 47 Actual frequency encoder6. FunctionalDescription