15ANTRIEBSTECHNIK6 1 1509.04.99KEB COMBIVERT F4-CName: Basis6© KEB Antriebstechnik, 1999All Rights reservedFunctional DescriptionChapter Section PageDateOperating and Appliance DisplaysAdr. min max defaultAdr. min max defaultAdr. min max defaultud.11!ud.11!ud.11!ud.11!202Dhru.45 Display analog option0,1 % -100-100This parameter displays the percentual value of the signal at the optional analog input.-10V...0...+10V = -100%...0...100%202Ehru.46 Ramp output frequency0,0125 Hz -409,58-409,58This parameter displays the frequency at the output of the ramp generator. If the internal PI-controller is not active, thedisplayed frequency corresponds to the output frequency ru.3.202Fhru.47 Actual frequency encoder0,0125 Hz -409,58-409,58The displayed value depends on cn.3.cn.3 = 0 (default) The actual frequency of ru.3 is displayed.cn.3 = 1 or 2 The current actual frequency of the encoder interface (option) is displayed. This measured valuecorresponds to the real slip-afflicted actual speed.1: channel 12: channel 2A counter-clockwise rotating field (reverse) is represented by a negative sign. Precondition is the correct phase connectionof the motor.For a closed-loop-controlled system it is imperative to ensure the correct correct phase connection, otherwisethe controllers would run into their limit.