706. Parameter Description6.1 US-ParametersPasswordWith different passwords different parameter groups can be accessedfor advanced programming.By selecting LoAd and pressing ENTER, all the LF parametersare returned to the factory default values. Note the display willautomatically change to show the value of LF. upon successfulloading of the default values.Adjustment value: LoAd = reset all LF parametersDisplayed responses: PASS = default successfulbdPAS = default not successfulLoad defaultsBy selecting LoAd and pressing ENTER, the selected configurationfile in US.10 and all the existing LF parameter values will be loadedinto the drive. Note: if the configuration is changed in US.10, the LFparameter values are returned to the factory default values. In thiscase, this should be done before any programming of the drive iscarried out as all parameters will be cleared. The display will changeautomatically to LF. upon successful loading of the configuration.The process may take several seconds.Adjustment value: LoAd = Load ConfigurationDisplayed responses: Pro9 = Loading configurationPASS = Load successfulbdPAS = Load not successfulLoad configurationThis parameter allows the user to select which mode the drive willoperate in. The possibilities are closed loop induction motor, closedloop permanent magnet motor, and low speed gearless modes. Selectfrom the list below and then load the configuration file into the drivethrough parameter US.4.Adjustment value: ICLSd = Closed loop inductionI9LSS = Closed loop induction gearlessPCLSd = Closed loop permanent magnetP9LSS = Closed loop permanent magnetgearlessSelect configurationParameter Description - Basic Set Up