86PM motor inductanceThis information is not used for induction motors and thereforethe parameter is not visible in induction motor mode.This is the total phase to phase reflected leakage inductance ofthe motor winding. The inductance listed on the manufacturer’sdata sheet will most likely be for one phase. So it will be necessaryto multiply the value by two and then enter it into the drive. Thisvalue can also be measured by the drive’s auto-tune function,see parameter LF.3. Incorrect settings of this parameter couldlead to oscillation in the current control since the regulator valuesfor the current control are calculated from this value.Unit: mHValue range: 0.01...500.00Default setting: 1.00Adjustment value: enter the value from the manufacturer’sdata sheet.This parameter not required for closed loop induction motoroperation and will not be visible in these modes.For PM motors enter the phase to phase resistance value.Some motor manufacturers list the per phase value thereforeyou must multiply by two. This value can also be measuredby the drive’s auto-tune function, see parameter LF.3. Incorrectsettings of this parameter could lead to oscillation in the currentcontrol and audible noise in the motor, since the regulator valuesfor the current control are calculated from this value.Unit: ohmsValue range: 0.000...4.Default setting: 1.000Adjustment value: enter the motor resistance valuePM motor resistanceParameter Description - Motor DataIMPMIMPM